Impact of botulinum toxin-A on corneal curvature assessed with Scheimpflug and Placido systems.
PURPOSE: To evaluate the effect of eyelid spasm treatment with botulinum toxin-A (BTX-A) on corneal curvature assessed with Scheimpflug (Pentacam) and Placido (Atlas) systems.
SETTING: Federal University of São Paulo, São Paulo, Brazil.
DESIGN: Prospective interventional case series.
METHODS: Patients with hemifacial spasm were evaluated. Steep keratometry (K) and corneal astigmatism (magnitudes and treatment-induced astigmatism) obtained with the Placido and Scheimpflug systems were evaluated before BTX-A application and after 15 days and 2, 3, and 4 months.
RESULTS: The study evaluated 48 eyes (24 affected and 24 normal contralateral eyes) of 24 patients. The mean steep K and astigmatism values obtained with the Placido system on the affected side before treatment were 46.91 diopters (D) ± 3.57 (SD) and 2.63 ± 2.46 D, respectively. A significant decrease in steep K (45.14 ± 1.20 D) and astigmatism (1.01 ± 0.58 D) was observed 2 months (P = .003 and P = .0004, respectively) and 3 months (45.64 ± 1.77 D and 1.36 ± 1.31 D, respectively) (P = .03 and P = .01, respectively) after treatment. The Scheimpflug system did not show significant changes in steep K measurements during the 4-month period. The mean astigmatism in the affected eye before treatment was 1.27 ± 0.88 D. A significant reduction was observed at 15 days (1.16 ± 1.16 D) and at 4 months (0.91 ± 0.59 D) (P = .02 and P = .03, respectively).
CONCLUSION: The Placido system was more sensitive in detecting a temporary reduction in corneal curvature after eyelid-spasm treatment.
FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.
SETTING: Federal University of São Paulo, São Paulo, Brazil.
DESIGN: Prospective interventional case series.
METHODS: Patients with hemifacial spasm were evaluated. Steep keratometry (K) and corneal astigmatism (magnitudes and treatment-induced astigmatism) obtained with the Placido and Scheimpflug systems were evaluated before BTX-A application and after 15 days and 2, 3, and 4 months.
RESULTS: The study evaluated 48 eyes (24 affected and 24 normal contralateral eyes) of 24 patients. The mean steep K and astigmatism values obtained with the Placido system on the affected side before treatment were 46.91 diopters (D) ± 3.57 (SD) and 2.63 ± 2.46 D, respectively. A significant decrease in steep K (45.14 ± 1.20 D) and astigmatism (1.01 ± 0.58 D) was observed 2 months (P = .003 and P = .0004, respectively) and 3 months (45.64 ± 1.77 D and 1.36 ± 1.31 D, respectively) (P = .03 and P = .01, respectively) after treatment. The Scheimpflug system did not show significant changes in steep K measurements during the 4-month period. The mean astigmatism in the affected eye before treatment was 1.27 ± 0.88 D. A significant reduction was observed at 15 days (1.16 ± 1.16 D) and at 4 months (0.91 ± 0.59 D) (P = .02 and P = .03, respectively).
CONCLUSION: The Placido system was more sensitive in detecting a temporary reduction in corneal curvature after eyelid-spasm treatment.
FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.
Full text links
Related Resources
Trending Papers
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app