We have located links that may give you full text access.
JOURNAL ARTICLE
OBSERVATIONAL STUDY
Automatic Video Analysis for Obstructive Sleep Apnea Diagnosis.
Sleep 2016 August 2
STUDY OBJECTIVES: We investigated the diagnostic accuracy for the identification of obstructive sleep apnea (OSA) and its severity of a noninvasive technology based on image processing (SleepWise).
METHODS: This is an observational, prospective study to evaluate the degree of agreement between polysomnography (PSG) and SleepWise. We recruited 56 consecutive subjects with suspected OSA who were referred as outpatients to the Sleep Unit of the Hospital Universitari Germans Trias i Pujol (HUGTiP) from January 2013 to January 2014. All patients underwent laboratory PSG and image processing with SleepWise simultaneously the same night. Both PSG and SleepWise analyses were carried independently and blindly.
RESULTS: We analyzed 50 of the 56 patients recruited. OSA was diagnosed through PSG in a total of 44 patients (88%) with a median apnea-hypopnea index (AHI) of 25.35 (24.9). According to SleepWise, 45 patients (90%) met the criteria for a diagnosis of OSA, with a median AHI of 22.8 (22.03). An analysis of the ability of PSG and SleepWise to classify patients by severity on the basis of their AHI shows that the two diagnostic systems distribute the different groups similarly. According to PSG, 23 patients (46%) had a diagnosis of severe OSA, 11 patients (22%) moderate OSA, and 10 patients (20%) mild OSA. According to SleepWise, 20, 13, and 12 patients (40%, 26%, and 24%, respectively) had a diagnosis of severe, moderate, and mild OSA respectively. For OSA diagnosis, SleepWise was found to have sensitivity of 100% and specificity of 83% in relation to PSG. The positive predictive value was 97% and the negative predictive value was 100%. The Bland-Altman plot comparing the mean AHI values obtained through PSG and SleepWise shows very good agreement between the two diagnostic techniques, with a bias of -3.85, a standard error of 12.18, and a confidence interval of -0.39 to -7.31.
CONCLUSIONS: SleepWise was reasonably accurate for noninvasive and automatic diagnosis of OSA in outpatients. SleepWise determined the severity of OSA with high reliability. The current study including simultaneous laboratory PSG and SleepWise processing image is proposed as a reasonable validation standard.
METHODS: This is an observational, prospective study to evaluate the degree of agreement between polysomnography (PSG) and SleepWise. We recruited 56 consecutive subjects with suspected OSA who were referred as outpatients to the Sleep Unit of the Hospital Universitari Germans Trias i Pujol (HUGTiP) from January 2013 to January 2014. All patients underwent laboratory PSG and image processing with SleepWise simultaneously the same night. Both PSG and SleepWise analyses were carried independently and blindly.
RESULTS: We analyzed 50 of the 56 patients recruited. OSA was diagnosed through PSG in a total of 44 patients (88%) with a median apnea-hypopnea index (AHI) of 25.35 (24.9). According to SleepWise, 45 patients (90%) met the criteria for a diagnosis of OSA, with a median AHI of 22.8 (22.03). An analysis of the ability of PSG and SleepWise to classify patients by severity on the basis of their AHI shows that the two diagnostic systems distribute the different groups similarly. According to PSG, 23 patients (46%) had a diagnosis of severe OSA, 11 patients (22%) moderate OSA, and 10 patients (20%) mild OSA. According to SleepWise, 20, 13, and 12 patients (40%, 26%, and 24%, respectively) had a diagnosis of severe, moderate, and mild OSA respectively. For OSA diagnosis, SleepWise was found to have sensitivity of 100% and specificity of 83% in relation to PSG. The positive predictive value was 97% and the negative predictive value was 100%. The Bland-Altman plot comparing the mean AHI values obtained through PSG and SleepWise shows very good agreement between the two diagnostic techniques, with a bias of -3.85, a standard error of 12.18, and a confidence interval of -0.39 to -7.31.
CONCLUSIONS: SleepWise was reasonably accurate for noninvasive and automatic diagnosis of OSA in outpatients. SleepWise determined the severity of OSA with high reliability. The current study including simultaneous laboratory PSG and SleepWise processing image is proposed as a reasonable validation standard.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app