BACKGROUND: Clinical studies for assessing the effectiveness and safety in a premarketing setting are conducted under time and cost constraints. In recent years, postmarketing data analysis has been given more attention. However, to our knowledge, no studies have compared the effectiveness and the safety between the pre- and postmarketing settings. In this study, we aimed to investigate the importance of the postmarketing data analysis using clinical data.

METHODS AND FINDINGS: Studies on capsule endoscopy with rich clinical data in both pre- and postmarketing settings were selected for the analysis. For effectiveness, clinical studies published before October 10, 2015 comparing capsule endoscopy and conventional flexible endoscopy measuring the detection ratio of obscure gastrointestinal bleeding were selected (premarketing: 4 studies and postmarketing: 8 studies) from PubMed (MEDLINE), Cochrane Library, EMBASE and Web of Science. Among the 12 studies, 5 were blinded and 7 were non-blinded. A time series meta-analysis was conducted. Effectiveness (odds ratio) decreased in the postmarketing setting (premarketing: 5.19 [95% confidence interval: 3.07-8.76] vs. postmarketing: 1.48 [0.81-2.69]). The change in odds ratio was caused by the increase in the detection ratio with flexible endoscopy as the control group. The efficacy of capsule endoscopy did not change between pre- and postmarketing settings. Heterogeneity (I2) increased in the postmarketing setting because of one study. For safety, in terms of endoscope retention in the body, data from the approval summary and adverse event reports were analyzed. The incidence of retention decreased in the postmarketing setting (premarketing: 0.75% vs postmarketing: 0.095%). The introduction of the new patency capsule for checking the patency of the digestive tract might contribute to the decrease.

CONCLUSIONS: Effectiveness and safety could change in the postmarketing setting. Therefore, time series meta-analyses could be useful to continuously monitor the effectiveness of medical device in clinical practices.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app