We have located links that may give you full text access.
Safety and efficacy of the nMARQ catheter for paroxysmal and persistent atrial fibrillation.
AIMS: Circular irrigated radiofrequency ablation using the nMARQ catheter has recently been introduced for the treatment of atrial fibrillation (AF). The aim of this study is to report the safety and efficacy of catheter ablation using this technology in patients with paroxysmal and persistent AF.
METHODS AND RESULTS: The data of a prospective registry describing the experience of a single operator using this technology on 327 consecutive patients were analysed. The mean procedure time was 69 ± 22 min for paroxysmal AF (n = 228) and 75 ± 23 min for persistent AF (n = 97). Follow-up was available for 206 (63%) patients for 6 ± 5 months (range 1-23, median 3.3). Single procedure success off antiarrhythmic drugs was 75% in paroxysmal AF and 52% in persistent AF. Including the 5% redo cases and those on antiarrhythmic medication, freedom from AF was documented in 90 and 83% of paroxysmal and persistent AF patients, respectively. There were no serious complications in the first 325 patients, but the last two consecutive patients (0.6%) developed atrio-oesophageal fistulas and had a fatal outcome. The catheter has been recalled from market.
CONCLUSION: The nMARQ catheter is a highly effective tool for treatment of paroxysmal and persistent AF. Nevertheless, the occurrence of life-threatening oesophageal fistulas is of major concern and requires further investigation.
METHODS AND RESULTS: The data of a prospective registry describing the experience of a single operator using this technology on 327 consecutive patients were analysed. The mean procedure time was 69 ± 22 min for paroxysmal AF (n = 228) and 75 ± 23 min for persistent AF (n = 97). Follow-up was available for 206 (63%) patients for 6 ± 5 months (range 1-23, median 3.3). Single procedure success off antiarrhythmic drugs was 75% in paroxysmal AF and 52% in persistent AF. Including the 5% redo cases and those on antiarrhythmic medication, freedom from AF was documented in 90 and 83% of paroxysmal and persistent AF patients, respectively. There were no serious complications in the first 325 patients, but the last two consecutive patients (0.6%) developed atrio-oesophageal fistulas and had a fatal outcome. The catheter has been recalled from market.
CONCLUSION: The nMARQ catheter is a highly effective tool for treatment of paroxysmal and persistent AF. Nevertheless, the occurrence of life-threatening oesophageal fistulas is of major concern and requires further investigation.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app