Even the Intraoperative Knowledge of Femoral Stem Anteversion Cannot Prevent Impingement in Total Hip Arthroplasty.

BACKGROUND: In this prospective study of 66 patients undergoing cementless total hip arthroplasty through a minimally invasive anterolateral approach, we evaluated the impact of an intraoperative hybrid combined anteversion technique on postoperative range of motion (ROM).

METHODS: After navigation of femoral stem anteversion, trial acetabular components were positioned manually, and their position recorded with navigation. Then, final components were implanted with navigation at the goals prescribed by the femur-first impingement detection algorithm. Postoperatively, three-dimensional computed tomographies were performed to determine achieved component position and model impingement-free ROM by virtual hip movement, which was compared with published values necessary for activities of daily living. This model was run a second time with the implants in the position selected by the surgeon rather than the navigation program. In addition, we researched into risk factors for ROM differences between the freehand and navigated cup position.

RESULTS: We found a lower flexion of 8.3° (8.8°, P < .001) and lower internal rotation of 9.2° (9.5°, P < .001) for the freehand implanted cups in contrast to a higher extension of 9.8° (11.8°, P < .001) compared with the navigation-guided technique. For activities of daily living, 58.9% (33/56) in the freehand group compared with 85.7% (48/56) in the navigation group showed free flexion (P < .001) and similarly 50.0% (28/56) compared with 76.8% (43/56) free internal rotation (P < .001). Body mass index, incision length, and cup size were identified as independent risk factors for reduced flexion and internal rotation in the freehand group.

CONCLUSION: For implementation of a combined anteversion algorithm, intraoperative alignment guides for accurate cup positioning are required using a minimally invasive anterolateral approach. Obese patients are especially at risk of cup malpositioning.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app