Myocardial Characterization Using Dual-Energy CT in Doxorubicin-Induced DCM: Comparison With CMR T1-Mapping and Histology in a Rabbit Model.

OBJECTIVES: This study sought to evaluate whether patterns of myocardial change in doxorubicin-induced dilated cardiomyopathy determined using dual-energy computed tomography (CT) were similar to characterization by extracellular volume fraction (ECV) using cardiac magnetic resonance (CMR) T1-mapping and collagen volume fraction (CVF) measured using histology.

BACKGROUND: Anthracycline chemoagents are effective against a wide range of malignant conditions. However, cardiotoxicity is a well-known adverse effect of these drugs. Dual-energy CT could be as useful as magnetic resonance (MR) to evaluate myocardial change in anthracycline-induced cardiotoxicity.

METHODS: A dilated cardiomyopathy rabbit model was generated by injecting 11 adult New Zealand rabbits with 1.0 mg/kg of doxorubicin twice weekly for 16 weeks. Contrast-enhanced dual-energy CT and pre-contrast and post-contrast T1-mapping CMR using a prototype modified Look-Locker inversion recovery on a clinical 3-T scanner were performed on 15 rabbits, including 4 control animals, to calculate ECV at baseline, and at 6, 12, and 16 weeks after doxorubicin administration.

RESULTS: The mean ECV values (%) on CT and CMR at 6, 12, and 16 weeks after modeling were significantly higher than those measured at baseline (CT ECV: 35.3%, 41.9%, 42.1% vs. 28.5%; MR ECV: 32.6%, 35.8%, 41.3% vs. 28.8%, respectively; all p < 0.001). CT ECV and MR ECV values were well correlated (r = 0.888; p < 0.001). Both were well correlated with CVF on histology (CT ECV vs. CVF, r = 0.925, p < 0.001 and MR ECV vs. CVF, r = 0.961, p < 0.001, respectively).

CONCLUSIONS: Dual-energy CT ECV correlated well with CMR and histology. Dual-energy CT is useful for characterizing doxorubicin-induced cardiomyopathy by measuring ECV fraction; however, further technical improvements are desirable to lower motion artifact and improve image quality of the iodine map.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app