A Technique to Allow Prone Positioning in the Spine Surgery Patient With Unstable Spine Fracture and Flail Segment Rib Fractures.
A & A Case Reports 2016 July 2
Two patients with unstable thoracic spine and flail segment rib fractures initially failed prone positioning on a Jackson spinal table used for posterior spinal instrumentation and fusion surgery. Both patients experienced rapid hemodynamic collapse. We developed a solution using the anterior portions of a thoracolumbosacral orthosis brace as chest supports to use during prone positioning, allowing both patients to undergo uncomplicated posterior spinal instrumentation and fusion surgeries with greater hemodynamic stability.