Journal Article
Multicenter Study
Randomized Controlled Trial
Add like
Add dislike
Add to saved papers

Impact of using two dialyzers in parallel on phosphate clearance in hemodialysis patients: a randomized trial.

Background: Dietary restriction and phosphate binders are the main interventions used to manage hyperphosphatemia in people on hemodialysis, but have limited efficacy. Modifying conventional dialysis regimens to enhance phosphate clearance as an alternative approach remains relatively unstudied.

Methods: This was a 10-week, 2-arm, randomized crossover study. Participants were prevalent dialysis patients ( n = 32) with consecutive serum phosphate levels >1.6 mmol/L and on stable doses of a phosphate binder. Following a 2-week run-in period, participants were randomized to initiate dialysis using two high flux dialyzers in parallel (blood flow ≥350 mL/min, dialysate flow 800 mL/min) or standard dialysis using one high flux dialyzer (blood flow ≥350 mL/min, dialysate flow of 800 mL/min). Each regimen was 3 weeks in duration. After a 2-week washout period, participants received the alternate regimen. The primary outcome was the mean difference in phosphate clearance by dialyzer strategy. Secondary outcomes were phosphate removal and pre-dialysis serum phosphate.

Results: Phosphate clearance for the double dialyzer strategy did not differ significantly from the single dialyzer strategy [mean difference 7.5 mL/min (95% confidence interval, 95% CI, -6.1, 21.0), P = 0.28]. There was no difference in total phosphate removal and pre-dialysis phosphate between the double and single dialyzer strategies [total phosphate removal mean difference -0.2 mmol (95% CI -4.1, 3.7), P = 0.93; pre-dialysis mean difference 0.01 mmol/L (95% CI -0.18, 0.21), P = 0.88]. There was no difference in the proportion of participants who experienced at least one episode of intradialytic hypotension (32 versus 47%, P = 0.13). A limitation of the study was frequent protocol deviations in the dialysis prescription.

Conclusions: In this study, the use of two dialyzers in parallel did not increase phosphate clearance, phosphate removal or pre-dialysis serum phosphorus when compared with a standard dialysis treatment strategy. Future studies should continue to evaluate novel methods of phosphate removal using conventional hemodialysis.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app