Temporary leadless pacing in a patient with severe device infection.
BMJ Case Reports 2016 May 18
A 64-year-old patient underwent implantation of a transcatheter pacing systems (TPS) for severe lead endocarditis. The patient experienced fever after a dental procedure. On the transoesophageal echocardiogram (TEE), vegetations were attached to the leads. Because the patient was pacemaker dependent, a temporary pacing lead had to be placed. After removal, however, he did not improve. A second TEE showed new vegetations. Ventricular fibrillation occurred spontaneously; so isoprenalin had to be stopped and a new lead was implanted. Vegetations appeared soon after the new temporary lead was placed. We used a TPS as a bridging device, followed by implantation of a resynchronisation system, and explantation of the TPS. After the Micra TPS was implanted, the patient recovered noticeably. All inflammation parameters were negative and an additional (18)F-fluorodeoxyglucose-positron emission tomography/CT imaging also proved to be negative. So a CRT-D device was then implanted, and the TCP was removed.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app