Importance of accurately assessing biomechanics of the cornea.
Current Opinion in Ophthalmology 2016 July
PURPOSE OF REVIEW: This article summarizes the state-of-the-art in clinical corneal biomechanics, including procedures in which biomechanics play a role, and the clinical consequences in terms of error in estimating intraocular pressure (IOP).
RECENT FINDINGS: Corneal biomechanical response to refractive surgery can be categorized into either stable alteration of surface shape and thus visual outcome, or unstable biomechanical decompensation. The stable response is characterized by central flattening and peripheral steepening that is potentiated in a stiffer cornea. Two clinical devices for assessing corneal biomechanics do not yet measure classic biomechanical properties, but rather provide assessment of corneal deformation response. Biomechanical parameters are a function of IOP, and both the cornea and sclera become stiffer as IOP increases. Any assessment of biomechanical parameters must include IOP, and one value of stiffness does not adequately characterize a cornea.
SUMMARY: Corneal biomechanics plays a role in the outcomes of any procedure in which lamellae are transected. Once the corneal structure has been altered in a manner that includes central thinning, IOP measurements with applanation tonometry are likely not valid, and other technologies should be used.
RECENT FINDINGS: Corneal biomechanical response to refractive surgery can be categorized into either stable alteration of surface shape and thus visual outcome, or unstable biomechanical decompensation. The stable response is characterized by central flattening and peripheral steepening that is potentiated in a stiffer cornea. Two clinical devices for assessing corneal biomechanics do not yet measure classic biomechanical properties, but rather provide assessment of corneal deformation response. Biomechanical parameters are a function of IOP, and both the cornea and sclera become stiffer as IOP increases. Any assessment of biomechanical parameters must include IOP, and one value of stiffness does not adequately characterize a cornea.
SUMMARY: Corneal biomechanics plays a role in the outcomes of any procedure in which lamellae are transected. Once the corneal structure has been altered in a manner that includes central thinning, IOP measurements with applanation tonometry are likely not valid, and other technologies should be used.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app