We have located links that may give you full text access.
Comment
Journal Article
Relationship of diastolic function to new or persistent electrocardiographic left ventricular hypertrophy.
Blood Pressure 2016
BACKGROUND: Persistence or development of Cornell product left ventricular hypertrophy (LVH) is associated with increased heart failure (HF) risk that is partly explained by greater LV systolic dysfunction. However, whether new or persistent Cornell product LVH during antihypertensive treatment is associated with worse LV diastolic function is unclear.
METHODS: Left ventricular diastolic function was examined in relation to year-3 ECG LVH in 377 hypertensive patients with a preserved LV ejection fraction (>45%) at year-3. Cornell product >2440 mm·ms defined ECG LVH.
RESULTS: In multivariate models adjusting for age, sex, change from baseline to year-3 systolic blood pressure, and baseline and change from baseline to year-3 Sokolow-Lyon voltage, persistent or new Cornell product LVH at year-3 remained associated with year-3 abnormal half filling time (OR 1.63, 95% CI 1.04-2.55 p = 0.034), with a trend toward higher odds of abnormal third filling time (OR 1.51, 95% CI 0.087 p = 0.087) and total filling time (OR 1.79, CI 0.98-3.27 p = 0.059).
CONCLUSION: In hypertensive patients undergoing antihypertensive therapy, persistence or development of Cornell product ECG LVH at year-3 follow-up is modestly associated with LV diastolic dysfunction. These findings suggest that diastolic dysfunction may be a mechanism via which changing ECG LVH influences HF risk.
METHODS: Left ventricular diastolic function was examined in relation to year-3 ECG LVH in 377 hypertensive patients with a preserved LV ejection fraction (>45%) at year-3. Cornell product >2440 mm·ms defined ECG LVH.
RESULTS: In multivariate models adjusting for age, sex, change from baseline to year-3 systolic blood pressure, and baseline and change from baseline to year-3 Sokolow-Lyon voltage, persistent or new Cornell product LVH at year-3 remained associated with year-3 abnormal half filling time (OR 1.63, 95% CI 1.04-2.55 p = 0.034), with a trend toward higher odds of abnormal third filling time (OR 1.51, 95% CI 0.087 p = 0.087) and total filling time (OR 1.79, CI 0.98-3.27 p = 0.059).
CONCLUSION: In hypertensive patients undergoing antihypertensive therapy, persistence or development of Cornell product ECG LVH at year-3 follow-up is modestly associated with LV diastolic dysfunction. These findings suggest that diastolic dysfunction may be a mechanism via which changing ECG LVH influences HF risk.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app