We have located links that may give you full text access.
JOURNAL ARTICLE
VALIDATION STUDIES
Screening for depression in older people on acute medical wards: the validity of the Edinburgh Depression Scale.
Age and Ageing 2016 July
BACKGROUND: depression is common in people with poor physical health, particularly within the acute medical in-patient setting. Co-morbid depression contributes to poor outcomes, and screening for depression in acute medical in-patients has been advocated. The Edinburgh Depression Scale (EDS) has been validated in a variety of general hospital patient groups, but not previously in older acute medical in-patients.
METHODS: one hundred and eighteen patients aged 65 and older on acute medical wards were assessed using a standardised diagnostic interview (Present State Examination-Schedules for Clinical Assessment in Neuropsychiatry) to identify depression according to ICD-10 criteria. They subsequently completed the EDS. The performance characteristics at a range of thresholds were compared, and receiver operating characteristic curve analysis was performed.
RESULTS: the optimal EDS cut-off for identifying ICD-10 depressive episode was 7/8, with a sensitivity of 88%, specificity of 77%, positive predictive value of 52% and negative predictive value of 96%. The area under the receiver operating characteristic curve was 0.91.
CONCLUSION: the EDS was shown to be a useful instrument for detecting clinical depression in older people on acute medical wards in this study. Its performance was equivalent to other validated screening instruments in this population. Our findings add further weight to using the EDS as a screening instrument for depression in multiple general hospital settings.
METHODS: one hundred and eighteen patients aged 65 and older on acute medical wards were assessed using a standardised diagnostic interview (Present State Examination-Schedules for Clinical Assessment in Neuropsychiatry) to identify depression according to ICD-10 criteria. They subsequently completed the EDS. The performance characteristics at a range of thresholds were compared, and receiver operating characteristic curve analysis was performed.
RESULTS: the optimal EDS cut-off for identifying ICD-10 depressive episode was 7/8, with a sensitivity of 88%, specificity of 77%, positive predictive value of 52% and negative predictive value of 96%. The area under the receiver operating characteristic curve was 0.91.
CONCLUSION: the EDS was shown to be a useful instrument for detecting clinical depression in older people on acute medical wards in this study. Its performance was equivalent to other validated screening instruments in this population. Our findings add further weight to using the EDS as a screening instrument for depression in multiple general hospital settings.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app