MR fingerprinting for rapid quantification of myocardial T 1 , T 2 , and proton spin density.
Magnetic Resonance in Medicine 2017 April
PURPOSE: To introduce a two-dimensional MR fingerprinting (MRF) technique for quantification of T1 , T2 , and M0 in myocardium.
METHODS: An electrocardiograph-triggered MRF method is introduced for mapping myocardial T1 , T2 , and M0 during a single breath-hold in as short as four heartbeats. The pulse sequence uses variable flip angles, repetition times, inversion recovery times, and T2 preparation dephasing times. A dictionary of possible signal evolutions is simulated for each scan that incorporates the subject's unique variations in heart rate. Aspects of the sequence design were explored in simulations, and the accuracy and precision of cardiac MRF were assessed in a phantom study. In vivo imaging was performed at 3 Tesla in 11 volunteers to generate native parametric maps.
RESULTS: T1 and T2 measurements from the proposed cardiac MRF sequence correlated well with standard spin echo measurements in the phantom study (R2 > 0.99). A Bland-Altman analysis revealed good agreement for myocardial T1 measurements between MRF and MOLLI (bias 1 ms, 95% limits of agreement -72 to 72 ms) and T2 measurements between MRF and T2 -prepared balanced steady-state free precession (bias, -2.6 ms; 95% limits of agreement, -8.5 to 3.3 ms).
CONCLUSION: MRF can provide quantitative single slice T1 , T2 , and M0 maps in the heart within a single breath-hold. Magn Reson Med 77:1446-1458, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
METHODS: An electrocardiograph-triggered MRF method is introduced for mapping myocardial T1 , T2 , and M0 during a single breath-hold in as short as four heartbeats. The pulse sequence uses variable flip angles, repetition times, inversion recovery times, and T2 preparation dephasing times. A dictionary of possible signal evolutions is simulated for each scan that incorporates the subject's unique variations in heart rate. Aspects of the sequence design were explored in simulations, and the accuracy and precision of cardiac MRF were assessed in a phantom study. In vivo imaging was performed at 3 Tesla in 11 volunteers to generate native parametric maps.
RESULTS: T1 and T2 measurements from the proposed cardiac MRF sequence correlated well with standard spin echo measurements in the phantom study (R2 > 0.99). A Bland-Altman analysis revealed good agreement for myocardial T1 measurements between MRF and MOLLI (bias 1 ms, 95% limits of agreement -72 to 72 ms) and T2 measurements between MRF and T2 -prepared balanced steady-state free precession (bias, -2.6 ms; 95% limits of agreement, -8.5 to 3.3 ms).
CONCLUSION: MRF can provide quantitative single slice T1 , T2 , and M0 maps in the heart within a single breath-hold. Magn Reson Med 77:1446-1458, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app