We have located links that may give you full text access.
Three-dimensional Doppler ultrasound findings in healthy wrist and finger tendon sheaths - can feeding vessels lead to misinterpretation in Doppler-detected tenosynovitis?
Arthritis Research & Therapy 2016 March 19
BACKGROUND: The aim was to investigate the presence of feeding vessels in or in close proximity to extensor and flexor tendon sheaths at the wrists level and in finger flexor tendon sheaths in healthy controls, using 3D ultrasound (US), which may cause pitfalls, in order to ensure correct interpretation of Doppler signals when diagnosing tenosynovitis.
METHOD: Forty healthy participants (20 women and 20 men age 23-67 years) without prior history of arthritis, tendon diseases or present pain in their hands were included. Twenty participants had 3D Doppler US of the second and third finger and twenty of the right wrist. US was carried out using a GE Logiq E9 unit with a 3D US probe. The colour Doppler settings were to published recommendation.
RESULTS: The feeding vessels in or in close proximity to the tendon sheaths were found in the flexor and extensor tendons sheaths at least once in each participant. No significant difference in feeding vessels was seen between the radial and carpal level in the wrist (p = 0.06) or between the second and third flexor tendon sheath (p = 0.84).
CONCLUSION: Doppler findings in or in close proximity to the tendon sheaths were common in wrists and fingers in healthy participants. These feeding vessels can be a source of error, not only due to their presence but also because they may be interpreted as being inside the tendon sheath due to blooming and reverberations artefacts. These vessels should be taken into consideration when diagnosing Doppler tenosynovitis.
METHOD: Forty healthy participants (20 women and 20 men age 23-67 years) without prior history of arthritis, tendon diseases or present pain in their hands were included. Twenty participants had 3D Doppler US of the second and third finger and twenty of the right wrist. US was carried out using a GE Logiq E9 unit with a 3D US probe. The colour Doppler settings were to published recommendation.
RESULTS: The feeding vessels in or in close proximity to the tendon sheaths were found in the flexor and extensor tendons sheaths at least once in each participant. No significant difference in feeding vessels was seen between the radial and carpal level in the wrist (p = 0.06) or between the second and third flexor tendon sheath (p = 0.84).
CONCLUSION: Doppler findings in or in close proximity to the tendon sheaths were common in wrists and fingers in healthy participants. These feeding vessels can be a source of error, not only due to their presence but also because they may be interpreted as being inside the tendon sheath due to blooming and reverberations artefacts. These vessels should be taken into consideration when diagnosing Doppler tenosynovitis.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app