We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
EX-PRESS® Implant Position and Function: Comparative Evaluation with Ultrasound Biomicroscopy and Optical Coherence Tomography.
Middle East African Journal of Ophthalmology 2016 January
PURPOSE: This study evaluated the feasibility of anterior segment optical coherence tomography (OCT) and ultrasound biomicroscopy (UBM) for the imaging of EX-PRESS(®) implant.
MATERIALS AND METHODS: This nonrandomized comparative case series was performed at the Department of Ophthalmology of the University Hospital of Heraklion, Crete, Greece. The Ellex Eye Cubed (40 MHz) UBM and the Zeiss Visante OCT systems were used. The filtering bleb morphology (BL), aqueous outflow (AS), and tube position (TB) were evaluated by two independent observers using a quality scale of 1 (worst) to 4 (best). Data were also collected on corneal and iris clearance from the tip of the tube (CC and IC, respectively). Data from both the devices were statistically analyzed. P < 0.05 was considered as statistically significant.
RESULTS: Ten eyes of 10 patients (6 males) with EX-PRESS(®) implant were examined. TB, AS, and BL scores using UBM were 2.40 ± 0.39, 3.45 ± 0.72, and 2.45 ± 0.64, respectively. TB, AS, and BL scores for OCT were 3.35 ± 0.41, 1.55 ± 0.43, and 2.55 ± 0.55, respectively. AS was significantly higher with UBM whereas the opposite was true for TB. Differences in BL between OCT and UBM were not statistically significant (P > 0.05).
CONCLUSION: Imaging of the EX-PRESS(®) implant is feasible with both UBM and OCT. Both modalities allow visualization of the position of the implant tube in relation to the iris or cornea and delineate the internal structure of the filtering bleb.
MATERIALS AND METHODS: This nonrandomized comparative case series was performed at the Department of Ophthalmology of the University Hospital of Heraklion, Crete, Greece. The Ellex Eye Cubed (40 MHz) UBM and the Zeiss Visante OCT systems were used. The filtering bleb morphology (BL), aqueous outflow (AS), and tube position (TB) were evaluated by two independent observers using a quality scale of 1 (worst) to 4 (best). Data were also collected on corneal and iris clearance from the tip of the tube (CC and IC, respectively). Data from both the devices were statistically analyzed. P < 0.05 was considered as statistically significant.
RESULTS: Ten eyes of 10 patients (6 males) with EX-PRESS(®) implant were examined. TB, AS, and BL scores using UBM were 2.40 ± 0.39, 3.45 ± 0.72, and 2.45 ± 0.64, respectively. TB, AS, and BL scores for OCT were 3.35 ± 0.41, 1.55 ± 0.43, and 2.55 ± 0.55, respectively. AS was significantly higher with UBM whereas the opposite was true for TB. Differences in BL between OCT and UBM were not statistically significant (P > 0.05).
CONCLUSION: Imaging of the EX-PRESS(®) implant is feasible with both UBM and OCT. Both modalities allow visualization of the position of the implant tube in relation to the iris or cornea and delineate the internal structure of the filtering bleb.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app