The Need for Standardized Methods for Measuring the Aorta: Multimodality Core Lab Experience From the GenTAC Registry.

OBJECTIVES: This study sought to evaluate variability in aortic measurements with multiple imaging modalities in clinical centers by comparing with a standardized measuring protocol implemented in a core laboratory.

BACKGROUND: In patients with aortic disease, imaging of thoracic aorta plays a major role in risk stratifying individuals for life-threatening complications and in determining timing of surgical intervention. However, standardization of the procedures for performance of aortic measurements is lacking.

METHODS: To characterize the diversity of methods used in clinical practice, we compared aortic measurements performed by echocardiography, computed tomography (CT), and magnetic resonance imaging (MRI) at the 6 GenTAC (National Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions) clinical centers to those performed at the imaging core laboratory in 965 studies. Each center acquired and analyzed their images according to local protocols. The same images were subsequently analyzed blindly by the core laboratory, on the basis of a standardized protocol for all imaging modalities. Paired measurements from clinical centers and core laboratory were compared by mean of differences and intraclass correlation coefficient (ICC).

RESULTS: For all segments of the ascending aorta, echocardiography showed a higher ICC (0.84 to 0.93) than CT (0.84) and MRI (0.82 to 0.90), with smaller mean of differences. MRI showed higher ICC for the arch and descending aorta (0.91 and 0.93). In a mixed adjusted model, the different imaging modalities and clinical centers were identified as sources of variability between clinical and core laboratory measurements, whereas age groups or diagnosis at enrollment were not.

CONCLUSIONS: By comparing core laboratory with measurements from clinical centers, our study identified important sources of variability in aortic measurements. Furthermore, our findings with regard to CT and MRI suggest a need for imaging societies to work toward the development of unifying acquisition protocols and common measuring methods.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app