Journal Article
Review
Add like
Add dislike
Add to saved papers

[Paradoxical low-flow low-gradient aortic stenosis].

Der Internist 2016 April
In approximately one third of patients presenting with suspected severe aortic stenosis, there is a discrepancy between a severely reduced aortic valve opening area (< 1 cm(2)) and a non-severe increase of the mean transvalvular gradient (< 40 mmHg). In a substantial number of these cases there is evidence of a severe paradoxical low-flow low-gradient aortic stenosis, characterized by a reduced stroke volume index in the setting of a normal left ventricular ejection fraction. This finding should trigger an extensive diagnostic work-up, including echocardiography, stress echocardiography and computed tomography to rule out measurement errors and to identify the cause(s) of the hemodynamic discrepancy. If the diagnosis of a severe paradoxical low-flow low-gradient aortic stenosis is confirmed and, furthermore, the patient is normotensive and reports stenosis-associated symptoms, the feasibility of an aortic valve replacement should be considered.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app