Accuracy of Adverse Event Ascertainment in Clinical Trials for Pediatric Acute Myeloid Leukemia.

PURPOSE: Reporting of adverse events (AEs) in clinical trials is critical to understanding treatment safety, but data on AE accuracy are limited. This study sought to determine the accuracy of AE reporting for pediatric acute myeloid leukemia clinical trials and to test whether an external electronic data source can improve reporting.

METHODS: Reported AEs were evaluated on two trials, Children's Oncology Group AAML03P1 and AAML0531 arm B, with identical chemotherapy regimens but with different toxicity reporting requirements. Chart review for 12 AEs for patients enrolled in AAML0531 at 14 hospitals was the gold standard. The sensitivity and positive predictive values (PPV) of the AAML0531 AE report and AEs detected by review of Pediatric Health Information System (PHIS) billing and microbiology data were compared with chart data.

RESULTS: Select AE rates from AAML03P1 and AAML0531 arm B differed significantly and correlated with the targeted toxicities of each trial. Chart abstraction was performed on 204 patients (758 courses) on AAML0531. AE report sensitivity was < 50% for eight AEs, but PPV was > 75% for six AEs. AE reports for viridans group streptococcal bacteremia, a targeted toxicity on AAML0531, had a sensitivity of 78.3% and PPV of 98.1%. PHIS billing data had higher sensitivity (> 50% for nine AEs), but lower PPV (< 75% for 10 AEs). Viridans group streptococcal detection using PHIS microbiology data had high sensitivity (92.3%) and PPV (97.3%).

CONCLUSION: The current system of AE reporting for cooperative oncology group clinical trials in pediatric acute myeloid leukemia underestimates AE rates. The high sensitivity and PPV of PHIS microbiology data suggest that using external data sources may improve the accuracy of AE reporting.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app