Add like
Add dislike
Add to saved papers

Preparation of Microvolume Anion-Exchange Cartridge for Inductively Coupled Plasma Mass Spectrometry-Based Determination of (237)Np Content in Spent Nuclear Fuel.

Analytical Chemistry 2016 March 16
Microvolume anion-exchange porous polymer disk-packed cartridges were prepared for Am/Np separation, which is required prior to the measurement of Neptunium-237 ((237)Np) with inductively coupled plasma mass spectrometry (ICPMS). Disks with a volume of 0.08 cm(3) were cut out from porous sheets having anion-exchange-group-containing polymer chains densely attached on the pore surface. Four different amine-based groups, N,N-dimethylaminoethyl methacrylate, trimethylammonium, diethylamine, and triethylenediamine (TEDA), were selected as the anion-exchange groups to be introduced into the porous sheets. The separation performances of Am/Np were evaluated using a standard solution of (243)Am, which had the same activity as its daughter nuclide (239)Np in secular equilibrium. (239)Np recovery of close to 100% with practically no contamination of (243)Am was achieved using the TEDA-introduced disk-packed cartridge. The time to elute (239)Np from the cartridge was approximately 40 s. The TEDA-introduced disk-packed cartridge was applied to the separation of Np from a spent nuclear fuel sample to confirm its separation performance. A known amount of (243)Am ((239)Np) was added to the spent nuclear fuel sample solution to monitor the chemical yield of Np. The chemical yield of Np calculated from a measured concentration of (239)Np was 90.4%. Am leakage in the Np-eluted solution was less than 1 ppt, corresponding to 0.001% of the original Am concentration in the sample. This indicates that no additional (239)Np was produced by the decay of the (243)Am remaining in the Np-eluted solution, thus providing a reliable chemical yield. U, which can cause a serious spectral interference involving the peak tail from the mass spectrum of (238)U, was thoroughly removed with the TEDA cartridge, providing interference-free measurement of (237)Np. The concentration of (237)Np obtained by ICPMS was 718 ± 12 ng/mg-U, which agrees well with the theoretically calculated value. Compared with the conventional separation technique using commercially available anion-exchange resin columns, the time required to adsorb, wash, and elute Np using the TEDA- introduced disk-packed cartridge was reduced by 75%.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app