JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Type IIIb Endoleak and Relining: A Mathematical Model of Distraction Forces.

PURPOSE: To examine the changes in distraction force following relining of a conventional abdominal aortic stent-graft with a type IIIb endoleak using the Nellix endovascular sealing device compared to a unilateral stent-graft.

METHODS: Relining is often used to repair type IIIb endoleaks, but the consequences to graft stability are unknown. A mathematical model was constructed based on pressure and volume flow through the stent-grafts, incorporating recognized distraction force equations. Steady flow was presumed at peak systolic pressures to calculate the maximum distraction force, with gravity ignored. Distraction forces for 28- to 36-mm-diameter stent-graft bodies with 16-mm limbs were calculated and compared to forces following relining with single and double Nellix devices or the Renu unilateral device.

RESULTS: Distraction forces for the 28-, 32-, and 36-mm stent-grafts prior to relining were 5.99, 10.21, and 14.99 N, respectively. Similar forces were reported after relining with bilateral Nellix devices (5.86, 10.08, and 14.86 N, respectively). However, use of a unilateral Nellix increased the distraction forces to 9.92, 14.14, and 18.92 N, respectively. These were comparable to the increase observed after relining with a Renu unilateral stent-graft (9.87, 14.09, and 18.86 N, respectively). The proportional increase in distraction force for a unilateral relining ranged from 26% to 66%, with the greatest increase noted in the smaller diameter main bodies.

CONCLUSION: Relining a stent-graft with a type IIIb endoleak using bilateral Nellix devices does not increase the distraction force. However, a unilateral Nellix device or the Renu system could theoretically increase the distraction force by up to 66%, potentially risking migration and type Ia endoleak. In clinical practice, these results suggest that a relining with bilateral Nellix may have benefits over the Renu unilateral stent-graft.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app