Retention efficacy and release of radioiodine in fume hoods.

Procedures to determine the release of hazardous gaseous substances including radioactive iodine are covered by different norms such as the European standard EN 14175 and the German national standard DIN 25466. The detection of sulphur hexafluoride (SF6 ) is required to comply with the prescribed methodology. The detection limit of this test is 4.5·10-7  mol/m3 in exhaust air. This detection limit would represent a very high activity in the region of 0.27 TBq/m3 leading to an unacceptable risk. We therefore developed a test using a filter system, consisting of a combination of filters capable of separating various chemical forms of airborne radioiodine. Air samples were collected directly in front of the fume hood and in the laboratory beside two different fume hoods of a similar construction with a final activated carbon filter for retention of radioiodine. Particular attention was therefore paid to air samples taken after passage over the filters. Significant differences in the degree of retention of iodine were found between the two fume hoods investigated. In one test a malfunction of the fume hood was demonstrated. In this case 0.148 × 10-3 % of the total released activity per m3 air was found 1 cm in front of the hood sash. A remarkably high fraction of the activity released in the fume hood (1.3 × 10-3 %/m3  air) was measured after the activated carbon filter. In the ambient air, values of up to 8.6 × 10-6 % pro m3 laboratory air sampled were measured, despite a 6-8-fold air exchange. The selected procedure is a factor of 1011 (Schomäcker et al., 2001) more sensitive than the standard recommended methods (EN 14175). The standard test prescribed by the DIN/EN failed to reveal any inadequacy in the protective function of the radionuclide hood with respect to radioiodine retention.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app