We have located links that may give you full text access.
Journal Article
Observational Study
Low Transmission of Airway Pressures to the Abdomen in Mechanically Ventilated Patients With or Without Acute Respiratory Failure and Intra-Abdominal Hypertension.
Journal of Intensive Care Medicine 2017 March
PURPOSE: Intra-abdominal pressure, measured at end expiration, may depend on ventilator settings and transmission of intrathoracic pressure. We determined the transmission of positive intrathoracic pressure during mechanical ventilation at inspiration and expiration into the abdominal compartment.
METHODS AND RESULTS: We included 9 patients after uncomplicated cardiac surgery and 9 with acute respiratory failure. Intravesical pressures were measured thrice (reproducibility of 1.8%) and averaged, at the end of each inspiratory and expiratory hold maneuvers of 5 seconds. Transmission, the change in intra-abdominal over intrathoracic pressures from end inspiration to end expiration, was about 8%. End-expiratory intra-abdominal pressure was lower than "total" intra-abdominal pressure over the entire respiratory cycle by 0.34 cm H2 O. It was 0.73 cm H2 O higher than "true" intra-abdominal pressure over the entire respiratory cycle, taking transmission into account. The percentage error was 3% for total and 10% for true pressure. Results did not differ among patients with or without acute respiratory failure and decreased respiratory compliance or between those with (≥12 mm Hg, n = 5) or without intra-abdominal hypertension.
CONCLUSIONS: Transmitted airway pressure only slightly affects intra-abdominal pressure in mechanically ventilated patients, irrespective of respiratory compliance and baseline intra-abdominal pressure values. End-expiratory measurements referenced against atmospheric pressure may suffice for clinical practice.
METHODS AND RESULTS: We included 9 patients after uncomplicated cardiac surgery and 9 with acute respiratory failure. Intravesical pressures were measured thrice (reproducibility of 1.8%) and averaged, at the end of each inspiratory and expiratory hold maneuvers of 5 seconds. Transmission, the change in intra-abdominal over intrathoracic pressures from end inspiration to end expiration, was about 8%. End-expiratory intra-abdominal pressure was lower than "total" intra-abdominal pressure over the entire respiratory cycle by 0.34 cm H2 O. It was 0.73 cm H2 O higher than "true" intra-abdominal pressure over the entire respiratory cycle, taking transmission into account. The percentage error was 3% for total and 10% for true pressure. Results did not differ among patients with or without acute respiratory failure and decreased respiratory compliance or between those with (≥12 mm Hg, n = 5) or without intra-abdominal hypertension.
CONCLUSIONS: Transmitted airway pressure only slightly affects intra-abdominal pressure in mechanically ventilated patients, irrespective of respiratory compliance and baseline intra-abdominal pressure values. End-expiratory measurements referenced against atmospheric pressure may suffice for clinical practice.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app