We have located links that may give you full text access.
Arthroscopic fixation for acute acromioclavicular joint disruption using the TightRope device.
Journal of Orthopaedic Surgery 2015 December
PURPOSE: To review outcome after arthroscopic fixation for acute acromioclavicular (AC) joint dislocation using the TightRope device.
METHODS: Records of 15 men and 2 women aged 19 to 52 (mean, 35) years who underwent arthroscopic fixation using the TightRope device for acute (<3 weeks) AC joint dislocation of Rockwood type III (n=6), type IV (n=1), and type V (n=10) were reviewed. Outcome was evaluated using the Constant score. The coracoclavicular (CC) distance before and after surgery was compared.
RESULTS: The mean follow-up period was 22.1 (range, 12-37) months. The mean time to return to work was 4 (range, 1.5-12) months, excluding one failure. The mean postoperative Constant score was 86.4 (range, 63-96). The CC distance decreased from 21.5±5.2 mm preoperatively to 9.8±3.5 mm at 6 months and to 10±3.2 mm at one year. There was no over-correction. All patients had satisfactory outcome except for one who had rupture of the TightRope suture at 6 months. Two patients had partial loss of reduction (≥2 mm) after 3 to 6 months secondary to osteolysis at the clavicular button site.
CONCLUSION: Arthroscopic fixation using the TightRope device for acute AC joint dislocation achieves satisfactory outcome.
METHODS: Records of 15 men and 2 women aged 19 to 52 (mean, 35) years who underwent arthroscopic fixation using the TightRope device for acute (<3 weeks) AC joint dislocation of Rockwood type III (n=6), type IV (n=1), and type V (n=10) were reviewed. Outcome was evaluated using the Constant score. The coracoclavicular (CC) distance before and after surgery was compared.
RESULTS: The mean follow-up period was 22.1 (range, 12-37) months. The mean time to return to work was 4 (range, 1.5-12) months, excluding one failure. The mean postoperative Constant score was 86.4 (range, 63-96). The CC distance decreased from 21.5±5.2 mm preoperatively to 9.8±3.5 mm at 6 months and to 10±3.2 mm at one year. There was no over-correction. All patients had satisfactory outcome except for one who had rupture of the TightRope suture at 6 months. Two patients had partial loss of reduction (≥2 mm) after 3 to 6 months secondary to osteolysis at the clavicular button site.
CONCLUSION: Arthroscopic fixation using the TightRope device for acute AC joint dislocation achieves satisfactory outcome.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app