CLINICAL TRIAL, PHASE III
COMPARATIVE STUDY
JOURNAL ARTICLE
MULTICENTER STUDY
RANDOMIZED CONTROLLED TRIAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

New insulin glargine 300 U/ml versus glargine 100 U/ml in Japanese people with type 2 diabetes using basal insulin and oral antihyperglycaemic drugs: glucose control and hypoglycaemia in a randomized controlled trial (EDITION JP 2).

AIMS: To compare the efficacy and safety of insulin glargine 300 U/ml (Gla-300) with glargine 100 U/ml (Gla-100) in Japanese people with type 2 diabetes using basal insulin plus oral antihyperglycaemic drug(s) [OAD(s)].

METHODS: The EDITION JP 2 study (NCT01689142) was a 6-month, multicentre, open-label, phase III study. Participants (n = 241, male 61%, mean diabetes duration 14 years, mean weight 67 kg, mean body mass index 25 kg/m(2), mean glycated haemoglobin (HbA1c) 8.02 %, mean basal insulin dose 0.24 U/kg/day) were randomized to Gla-300 or Gla-100, while continuing OAD(s). Basal insulin was titrated to target fasting self-monitored plasma glucose 4.4-5.6 mmol/l. The primary efficacy endpoint was HbA1c change over 6 months. Safety endpoints included hypoglycaemia and weight change.

RESULTS: Gla-300 was non-inferior to Gla-100 for HbA1c reduction [least squares (LS) mean difference 0.10 (95% confidence interval [CI] -0.08, 0.27) %]. The mean HbA1c at month 6 was 7.56 and 7.52 % with Gla-300 and Gla-100, respectively. Nocturnal confirmed (≤3.9 mmol/l) or severe hypoglycaemia risk was 38% lower with Gla-300 versus Gla-100 [relative risk 0.62 (95% CI 0.44, 0.88)]; annualized rates were 55% lower at night [rate ratio 0.45 (95% CI 0.21, 0.96)] and 36% lower at any time [24 h; rate ratio 0.64 (95% CI 0.43, 0.96)]. Severe hypoglycaemia was infrequent. A significant between-treatment difference in weight change favoured Gla-300 [LS mean difference -1.0 (95% CI -1.5, -0.5) kg; p = 0.0003]. Adverse event rates were comparable between groups.

CONCLUSIONS: Japanese people with type 2 diabetes using basal insulin plus OAD(s) experienced less hypoglycaemia with Gla-300 than with Gla-100, while glycaemic control did not differ.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app