Effect of extracorporeal CO2 removal on right ventricular and hemodynamic parameters in a patient with acute respiratory distress syndrome.
Perfusion 2016 September
We present a female patient with severe acute respiratory distress syndrome (ARDS) necessitating intubation and mechanical ventilation on the intensive care unit (ICU). High ventilatory pressures were needed because of hypoxia and severe hypercapnia with respiratory acidosis, resulting in right ventricular dysfunction with impaired haemodynamic stability. A veno-venous extracorporeal CO2 removal (ECCO2R) circuit was initiated, effectively eliminating carbon dioxide while improving oxygenation and enabling a reduction in applied ventilatory pressures. We noted a marked improvement of right ventricular function with restoration of haemodynamic stability. Within one week, the patient was weaned from both ECCO2R and mechanical ventilation. Besides providing adequate gas exchange, extracorporeal assist devices may be helpful in ameliorating right ventricular dysfunction during ARDS.