Clinical Results of Left Atrial Appendage Closure with Watchman Device in Patients with Atrial Fibrillation.

BACKGROUND: In patient with non-valvular atrial fibrillation (AF), over 90% of thrombus accumulation originates in the left atrial appendage (LAA). Warfarin significantly reduces risk of stroke. However, long-term anticoagulant therapy is associated with a significant risk of major bleeding, particularly in elderly. Transcatheter occlusion of left atrial appendage with Watchman device has proved to be non-inferior to warfarin in preventing stroke in non-valvular AF patients. No previous report of transcatheter occlusion of LAA was found in Thailand

OBJECTIVE: To evaluate short-term results of left atrial appendage closure with the Watchman® device in patient with non-valvular AF performed at King Chulalongkorn Memorial Hospital (KCMH).

MATERIAL AND METHOD: Between November 2012 and December 2014, 12 consecutives patients underwent percutaneous transcatheter left atrial appendage closure. Data included patient's characteristics, embolic risk factors, bleeding risk score, procedural finding, complications, in-hospital outcomes, and antithrombotic management were retrospectively reviewed

RESULTS: Percutaneous LAA occlusion was successfully performed in all 12 patients. The mean age was 71.2 ± 8.1 years. The history of previous bleeding was seen in four patients (33%). All patients had good left ventricular systolic function. The mean CHADS2 score was 3.2 ± 1.3, the mean CHA2DS2-VASc score was 4.8 ± 1.6 and the mean HAS-BLED score was 2.5 ± 0.9. The average LAA orifice diameter was 21.7 ± 3.4 mm, and the median implant size was 27.0 mm. The compression ratio was 15.2 ± 6.2%. Three patients (25%) were performed under general anesthesia, nine patients (75%) were performed with local anesthesia. The averageprocedure time was 61.2 ± 18.5 minutes. The average fluoroscopy time was 6.8 ± 3.3 minutes. There was no device embolization or pericardial effusion. There was no periprocedural cerebral event, assess site bleeding, or death during hospital admission. Mild peridevice leak was observed in three patients (25%), and all had disappeared on TEE performed at the 45-day follow-up. The median length of stay was two days.

CONCLUSION: The result of the present study showed that percutaneous LAA occlusion with the Watchman device was feasible and safe. The successfulness of the procedures and periprocedural complications were similar to standard in literature.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app