Add like
Add dislike
Add to saved papers

HTRF: a technology tailored for biomarker determination-novel analytical detection system suitable for detection of specific autoimmune antibodies as biomarkers in nanogram level in different body fluids.

BACKGROUND: Classical methods of gene product analysis such as binding assays (e.g., ELISA, protein chip technology) are generally time-consuming, lab-intensive, less sensitive, and lack high-throughput capacity. In addition, all existing methods used to measure proteins necessitate multiple divisions of the original sample and individual tests carried out for each substance, with an associated cost for each test.

METHOD: Together with a small biotech company, we developed a new and innovative analytical detection system based on homogenous time-resolved fluorescence (HTRF) technology. Our system facilitates the development of immune assays that measure selective different analytes such as selected biomarkers in a small sample volume at less than 20 min with a much higher sensitivity compared to common binding assay systems such as enzyme-linked immunosorbent assay (ELISA). Recent advances of the application of this novel detection system combine the power of miniaturization, microfluidics, better linear range, and faster quantification.

RESULTS: The power of the HTRF technology offers great promise for point-of-care clinical testing and monitoring of many important analytes such as disease-specific biomarkers in the nanogram level in different human body fluids such as CSF, blood, serum, plasma, and saliva. The linear dynamical range of our HTRF assay was determined between 2.5 and 100 ng/mL. Precision and accuracy calculated for inter- as well as intra-assays was less than ± 10 %. Intra-assay and inter-assay precision for high, medium, and low analyte concentrations show mean CV values less than ± 10 %. Intra- and inter-assay accuracy for all three concentrations show mean recovery values of 80-120 %.

CONCLUSION: The aim of this work is to describe the development and establishment of this novel HTRF system that allows the very fast detection and quantification of biomarkers in different human body fluids. Furthermore, a specific antibody combination that assures a specific binding of the correct refolded autoimmune IgG is evaluated.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app