Expanding Endovascular Therapy of Very Small Ruptured Aneurysms with the 1.5-mm Coil.

BACKGROUND: Very small ruptured aneurysms (≤3 mm) demonstrate a significant risk for procedural rupture with endovascular therapy. Since 2007, 1.5-mm-diameter coils have been available (Micrus, Microvention, and ev3), allowing neurointerventionalists the opportunity to offer patients with very small aneurysms endovascular treatment. In this study, we review the clinical and angiographic outcome of patients with very small ruptured aneurysms treated with the 1.5-mm coil.

METHODS: This is a retrospective cohort study in which we examined consecutive ruptured very small aneurysms treated with coil embolization at a single institution. The longest linear aneurysm was recorded, even if the first coil was sized to a smaller transverse diameter. Very small aneurysms were defined as ≤3 mm. Descriptive results are presented.

RESULTS: From July 2007 to March 2015, 81 aneurysms were treated acutely with coils in 78 patients presenting with subarachnoid hemorrhage. There were 5 patients with 3-mm aneurysms, of which the transverse diameter was ≤2 mm in 3 patients. In all 5 patients, a balloon was placed for hemostatic prophylaxis in case of rupture, and a single 1.5-mm coil was inserted for aneurysm treatment without complication. Complete aneurysm occlusion was achieved in 1 patient, residual neck in 2, and residual aneurysm in 2 patients. Aneurysm recanalization was present in 2 patients with an anterior communicating artery aneurysm; a recoiling attempt was unsuccessful in 1 of these 2 patients due to inadvertent displacement and distal coil embolization, but subsequent surgical clipping was successful. Another patient was retreated by surgical clipping for a residual wide-neck carotid terminus aneurysm. One patient died of ventriculitis 3 weeks after presentation; all 4 other patients had an excellent outcome with no rebleed at follow-up (mean 21 months, range 1-62).

CONCLUSION: The advent of the 1.5-mm coil may be used in the endovascular treatment of patients with very small ruptured aneurysms, providing a temporary protection to the site of rupture in the acute phase. If necessary, bridging with elective clipping may provide definitive aneurysm treatment.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app