CASE REPORTS
JOURNAL ARTICLE
REVIEW
Add like
Add dislike
Add to saved papers

Obstetric Neuraxial Drug Administration Errors: A Quantitative and Qualitative Analytical Review.

BACKGROUND: Drug administration errors in obstetric neuraxial anesthesia can have devastating consequences. Although fully recognizing that they represent "only the tip of the iceberg," published case reports/series of these errors were reviewed in detail with the aim of estimating the frequency and the nature of these errors.

METHODS: We identified case reports and case series from MEDLINE and performed a quantitative analysis of the involved drugs, error setting, source of error, the observed complications, and any therapeutic interventions. We subsequently performed a qualitative analysis of the human factors involved and proposed modifications to practice.

RESULTS: Twenty-nine cases were identified. Various drugs were given in error, but no direct effects on the course of labor, mode of delivery, or neonatal outcome were reported. Four maternal deaths from the accidental intrathecal administration of tranexamic acid were reported, all occurring after delivery of the fetus. A range of hemodynamic and neurologic signs and symptoms were noted, but the most commonly reported complication was the failure of the intended neuraxial anesthetic technique. Several human factors were present; most common factors were drug storage issues and similar drug appearance. Four practice recommendations were identified as being likely to have prevented the errors.

CONCLUSIONS: The reported errors exposed latent conditions within health care systems. We suggest that the implementation of the following processes may decrease the risk of these types of drug errors: (1) Careful reading of the label on any drug ampule or syringe before the drug is drawn up or injected; (2) labeling all syringes; (3) checking labels with a second person or a device (such as a barcode reader linked to a computer) before the drug is drawn up or administered; and (4) use of non-Luer lock connectors on all epidural/spinal/combined spinal-epidural devices. Further study is required to determine whether routine use of these processes will reduce drug error.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app