Add like
Add dislike
Add to saved papers

Secondary Radial Nerve Palsy after Minimally Invasive Plate Osteosynthesis of a Distal Humeral Shaft Fracture.

Minimally invasive plate osteosynthesis is a widely used procedure for the treatment of fractures of the femur and the tibia. For a short time it is also used for the treatment of humeral shaft fractures. Among other advantages, the ambassadors of this technique emphasize the lower risk of nerve injuries when compared to open reduction and internal fixation. We report the case of secondary radial nerve palsy caused by percutaneous fixation of a plate above the antecubital fold. The nerve did not recover and the patient needed a tendon transfer to regain active extension of the fingers. This case points to the importance of adequate exposure of the bone and plate if a humeral shaft fracture extends far distally.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app