Add like
Add dislike
Add to saved papers

Pulse Pressure Variation Adjusted by Respiratory Changes in Pleural Pressure, Rather Than by Tidal Volume, Reliably Predicts Fluid Responsiveness in Patients With Acute Respiratory Distress Syndrome.

Critical Care Medicine 2016 Februrary
OBJECTIVES: 1) To evaluate the ability of pulse pressure variation adjusted by respiratory changes in pleural pressure to predict fluid responsiveness compared with pulse pressure variation alone. 2) To identify factors explaining the poor performance of pulse pressure variation in acute respiratory distress syndrome.

DESIGN: Prospective study.

SETTING: Forty-bed university hospital general ICU.

PATIENTS: Ninety-six mechanically ventilated acute respiratory distress syndrome patients requiring fluid challenge.

INTERVENTIONS: Fluid challenge, 500 mL saline over 20 minutes.

MEASUREMENTS AND MAIN RESULTS: Before fluid challenge, esophageal pressure was measured at the end-inspiratory and end-expiratory occlusions. Change in pleural pressure was calculated as the difference between esophageal pressure measured at end-inspiratory and end-expiratory occlusions. Hemodynamic measurements were obtained before and after the fluid challenge. Patients were ventilated with tidal volume 7.0 ± 0.8 mL/kg predicted body weight. The fluids increased cardiac output by greater than 15% in 52 patients (responders). Adjusting pulse pressure variation for changes in pleural pressure (area under the receiver operating characteristic curve, 0.94 [0.88-0.98]) and the ratio of chest wall elastance to total respiratory system elastance (area under the receiver operating characteristic curve, 0.93 [0.88-0.98]) predicted fluid responsiveness better than pulse pressure variation (area under the receiver operating characteristic curve, 0.78 [0.69-0.86]; all p < 0.01). The gray zone approach identified a range of pulse pressure variation/changes in pleural pressure values (1.94-2.1) in 3.1% of patients for whom fluid responsiveness could not be predicted reliably. On logistic regression analysis, two independent factors affected the correct classification of fluid responsiveness at a 12% pulse pressure variation cutoff: tidal volume (adjusted odds ratio 1.57/50 mL; 95% CI, 1.05-2.34; p = 0.027) and chest wall elastance/respiratory system elastance (adjusted odds ratio, 2.035/0.1 unit; 95% CI, 1.36-3.06; p = 0.001). In patients with chest wall elastance/respiratory system elastance above the median (0.28), pulse pressure variation area under the receiver operating characteristic curve was 0.94 (95% CI, 0.84-0.99) compared with 0.76 (95% CI, 0.61-0.87) otherwise (p = 0.02).

CONCLUSIONS: In acute respiratory distress syndrome patients, pulse pressure variation adjusted by changes in pleural pressure is a reliable fluid responsiveness predictor despite the low tidal volume (< 8 mL/kg). The poor predictive ability of pulse pressure variation in acute respiratory distress syndrome patients is more related to low chest wall elastance/respiratory system elastance ratios than to a low tidal volume.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app