Comparative Study
Evaluation Studies
Journal Article
Research Support, Non-U.S. Gov't
Validation Studies
Add like
Add dislike
Add to saved papers

Comparison between Folin-Ciocalteu and Prussian Blue Assays to Estimate The Total Phenolic Content of Juices and Teas Using 96-Well Microplates.

UNLABELLED: Folin-Ciocalteu colorimetric assay (FC) is the most widely used assay to estimate the total phenolic content in foods, beverages, herbs and other plant extracts, but many chemical compounds may act as interfering agents, producing inaccurate estimations of the real concentration of phenolic compounds in the matrix. Based on this limitation, the objective of this study was to compare, quantitatively, the Folin-Ciocalteu and Prussian Blue (PB) assays in estimating the total phenolic content in purple grape juices (n = 20; Vitis labrusca L.) and teas (n = 25) from different botanical origins using 96-well microplates. PB assay presented a low limit of detection (PB = 0.27 mg/L; FC = 0.25 mg/L) and quantification (PB = 0.92 mg/L; FC = 0.82 mg/L), showing its suitability in screening the total phenolic content in grape juices and teas. FC and PB assays presented a high association (P < 0.0001) for teas (r = 0.887) and grape juices (r = 0.923). The advantages of PB over FC assay are its simplicity, low time consumption (15 min reaction as compared to 60 min reaction for the FC assay), lower usage of reagents (solutions are prepared in a mM base), and higher selectivity. Additionally, PB assay was proven to be reproducible and repeatable and, therefore, may be used as an alternative to FC assay.

PRACTICAL APPLICATION: Prussian Blue assay (PB) has been used as an alternative to Folin-Ciocalteu assay (FC) to estimate the total content of phenolic compounds in herbs and some natural products. In our study we showed that the advantages of PB assay over FC are its simplicity, low time consumption (15 min reaction as compared to 60 min reaction for the FC assay), lower usage of reagents (solutions are prepared in a mM base) and higher selectivity as compared to FC assay. Additionally, PB assay was proven to be reproducible and repeatable and, therefore, may be used as an alternative to FC assay.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app