Myopic Shift during Hyperbaric Oxygenation Attributed to Lens Index Changes.
Optometry and Vision Science : Official Publication of the American Academy of Optometry 2015 November
PURPOSE: To examine ocular lens parameters and structural changes to elucidate mechanisms underlying the myopic shift and cataract-related changes that occur in some patients during hyperbaric oxygen (HBO) therapy.
METHODS: Scheimpflug images (Nidek EAS-1000) of the crystalline lens, measurements of scattered light, objective refraction, keratometry, tonometry, and axial length of the eye were obtained after the first day of HBO therapy and repeated when patients had completed 19 days of the treatment.
RESULTS: Significant reduction in mean (± SD) optical density was found in the lens nucleus, -2.8 (± 4.3) units (p = 0.009) and -2.2 (± 4.1) units (p = 0.027) within circular and oval areas, respectively. Significant decrease in mean (± SD) backward scattered light was measured, -0.4 (± 0.8) units (p = 0.022). Mean (± SD) myopic shift was -0.58 (± 0.39) diopters (p < 0.001), whereas cortical optical density, forward scattered light, lenticular parameters, keratometry, tonometry, anterior chamber depth, and axial length of the eye appeared unchanged.
CONCLUSIONS: Transient myopic shift reported in patients during HBO therapy is attributed to changes in the refractive index of the lens. No changes in lens curvatures or thickness were found after treatment.
METHODS: Scheimpflug images (Nidek EAS-1000) of the crystalline lens, measurements of scattered light, objective refraction, keratometry, tonometry, and axial length of the eye were obtained after the first day of HBO therapy and repeated when patients had completed 19 days of the treatment.
RESULTS: Significant reduction in mean (± SD) optical density was found in the lens nucleus, -2.8 (± 4.3) units (p = 0.009) and -2.2 (± 4.1) units (p = 0.027) within circular and oval areas, respectively. Significant decrease in mean (± SD) backward scattered light was measured, -0.4 (± 0.8) units (p = 0.022). Mean (± SD) myopic shift was -0.58 (± 0.39) diopters (p < 0.001), whereas cortical optical density, forward scattered light, lenticular parameters, keratometry, tonometry, anterior chamber depth, and axial length of the eye appeared unchanged.
CONCLUSIONS: Transient myopic shift reported in patients during HBO therapy is attributed to changes in the refractive index of the lens. No changes in lens curvatures or thickness were found after treatment.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app