Effectiveness of Rehabilitative Balloon Swallowing Treatment on Upper Esophageal Sphincter Relaxation and Pharyngeal Motility for Neurogenic Dysphagia.

OBJECTIVE: To investigate the relationship between dysphagia severity and opening of the upper esophageal sphincter (UES), and to assess the effect of balloon size on functional improvement after rehabilitative balloon swallowing treatment in patients with severe dysphagia with cricopharyngeus muscle dysfunction (CPD).

METHODS: We reviewed videofluoroscopic swallowing studies (VFSS) conducted in the Department of Physical Medicine and Rehabilitation, Myongji Hospital from January through December in 2012. All subjects diagnosed with CPD by VFSS further swallowed a 16-Fr Foley catheter filled with barium sulfate suspension for three to five minutes. We measured the maximum diameter of the balloon that a patient could swallow into the esophagus and subsequently conducted a second VFSS. Then, we applied a statistical technique to correlate the balloon diameter with functional improvement after the balloon treatment.

RESULTS: Among 283 inpatients who received VFSS, 21 subjects were diagnosed with CPD. It was observed that the degree of UES opening evaluated by swallowing a catheter balloon had inverse linear correlations with pharyngeal transit time and post-swallow pharyngeal remnant. Videofluoroscopy guided iterative balloon swallowing treatment for three to five minutes, significantly improved the swallowing ability in terms of pharyngeal transit time and pharyngeal remnant (p<0.005 and p<0.001, respectively). Correlation was seen between balloon size and reduction in pharyngeal remnants after balloon treatment (Pearson correlation coefficient R=-0.729, p<0.001), whereas there was no definite relationship between balloon size and improvement in pharyngeal transit time (R=-0.078, p=0.738).

CONCLUSION: The maximum size of the balloon that a patient with CPD can swallow possibly indicates the maximum UES opening. The iterative balloon swallowing treatment is safe without the risk of aspiration, and it can be an effective technique to improve both pharyngeal motility and UES relaxation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app