We have located links that may give you full text access.
Clinical Trial
Comparative Study
Journal Article
SMILE Procedures With Four Different Cap Thicknesses for the Correction of Myopia and Myopic Astigmatism.
Journal of Refractive Surgery 2015 September
PURPOSE: To study the feasibility of performing myopic femtosecond small incision lenticule extraction (SMILE) with four different cap thicknesses (130, 140, 150, and 160 μm).
METHODS: In this retrospective, comparative, non-randomized clinical trial, a refractive lenticule of intrastromal corneal tissue was cut with the VisuMax femtosecond laser system (Carl Zeiss Meditec AG, Jena, Germany) using different depths of the non-refractive lenticule cut. Manifest refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and Objective Scattering Index (OSI) were evaluated. Minimum follow-up time was 1 year.
RESULTS: Ninety-four eyes of 47 patients with myopia with (14 patients) and without (33 patients) astigmatism were treated. One year after the surgery, mean log-MAR UDVA, logMAR CDVA, SE, and OSI were 0.07 ± 0.12, 0.01 ± 0.37, 0.07 ± 0.57, and 0.88 ± 0.17, respectively (P < .05). There were no significant statistical differences in logMAR UDVA, logMAR CDVA, SE, or OSI (P > .05) variables when the different groups were compared for the same periods of time.
CONCLUSIONS: No differences in visual acuity, refractive outcomes in optical visual quality, or complications were observed when using SMILE at four different depths.
METHODS: In this retrospective, comparative, non-randomized clinical trial, a refractive lenticule of intrastromal corneal tissue was cut with the VisuMax femtosecond laser system (Carl Zeiss Meditec AG, Jena, Germany) using different depths of the non-refractive lenticule cut. Manifest refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and Objective Scattering Index (OSI) were evaluated. Minimum follow-up time was 1 year.
RESULTS: Ninety-four eyes of 47 patients with myopia with (14 patients) and without (33 patients) astigmatism were treated. One year after the surgery, mean log-MAR UDVA, logMAR CDVA, SE, and OSI were 0.07 ± 0.12, 0.01 ± 0.37, 0.07 ± 0.57, and 0.88 ± 0.17, respectively (P < .05). There were no significant statistical differences in logMAR UDVA, logMAR CDVA, SE, or OSI (P > .05) variables when the different groups were compared for the same periods of time.
CONCLUSIONS: No differences in visual acuity, refractive outcomes in optical visual quality, or complications were observed when using SMILE at four different depths.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app