We have located links that may give you full text access.
CLINICAL TRIAL
COMPARATIVE STUDY
JOURNAL ARTICLE
MULTICENTER STUDY
RESEARCH SUPPORT, NON-U.S. GOV'T
Paclitaxel-eluting balloon and everolimus-eluting stent for provisional stenting of coronary bifurcations: 12-month results of the multicenter BIOLUX-I study.
BACKGROUND: Several studies investigated the combination of bare metal stents in the main branch and drug-eluting balloons in the side branch in bifurcation lesions, but data on the combination of drug-eluting stents and drug-eluting balloons are scarce. We aim to assess the feasibility of provisional stenting with an everolimus-eluting stent in the main branch and a paclitaxel-eluting balloon in the side branch.
METHODS: In this prospective, multi-center study conducted in 5 Australian sites, 35 patients with bifurcation lesions were enrolled. Angiographic and intravascular ultrasound assessments were conducted at 9 months; clinical follow-up was conducted until 12 months.
RESULTS: The primary endpoint, late lumen loss in the side branch measured by quantitative coronary angiography, was 0.10±0.43mm. No binary restenosis was observed. One patient died; 3 myocardial infarctions (one suspected and two in non-target vessels) and one target lesion revascularization occurred. No probable or definite stent thrombosis was observed.
CONCLUSION: The combination of an everolimus-eluting stent in the main branch and a paclitaxel-eluting balloon in the side branch appears to be a safe, effective and novel treatment option for bifurcation lesions.
METHODS: In this prospective, multi-center study conducted in 5 Australian sites, 35 patients with bifurcation lesions were enrolled. Angiographic and intravascular ultrasound assessments were conducted at 9 months; clinical follow-up was conducted until 12 months.
RESULTS: The primary endpoint, late lumen loss in the side branch measured by quantitative coronary angiography, was 0.10±0.43mm. No binary restenosis was observed. One patient died; 3 myocardial infarctions (one suspected and two in non-target vessels) and one target lesion revascularization occurred. No probable or definite stent thrombosis was observed.
CONCLUSION: The combination of an everolimus-eluting stent in the main branch and a paclitaxel-eluting balloon in the side branch appears to be a safe, effective and novel treatment option for bifurcation lesions.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app