Outcomes of combined phacoemulsification and deep sclerectomy: a 10-year UK single-centre study.
Eye 2015 November
PURPOSE: To report the outcomes of combined phacoemulsification and -deep sclerectomy (phaco-DS) from a single UK centre over a 10-year period.
METHODS: Retrospective analysis of phaco-DS data extracted from an ongoing glaucoma surgery database within Calderdale and Huddersfield NHS Trust. Two hundred and ninety-six eyes of 282 patients were included. Data included patient demographics, pre- and postoperative intraocular pressure (IOP), use of mitomycin C (MMC), spacer device implantation, and follow-up details including surgical success rates. IOP success criteria were: (A) IOP <19 mm Hg and/or 20% decrease from baseline and (B) IOP <16 mm Hg and/or 30% drop from baseline.
RESULTS: Mean follow-up was 63.5 ± 35.3 months. MMC was applied in 145 eyes (49%). Kaplan-Meier success rates in all eyes for criteria A were 89.1% and 80% with glaucoma medications (qualified success) and 81.2% and 68.3% without medications (unqualified success) at 2 and 5 years, respectively. Qualified success for criteria B was 72.4 and 61.4% and unqualified rates were 67.2 and 55.2% for the same time periods. Repeated-measures ANOVA showed significantly lower IOP in the phaco-DS with MMC group up to 3 years postoperatively (P = 0.002). Cox's proportional hazards for criteria B, however, showed no significant effect of MMC application in the long term (P = 0.2). Increasing age and laser goniopuncture were positively associated with success, whereas the absence of spacer devices was negatively associated. At last follow-up, 20% of eyes were on glaucoma medications. Complication rates were low with hypotony rates of 0.68%.
CONCLUSIONS: This study confirms the long-term safety and efficacy of phaco-DS as a primary glaucoma procedure.
METHODS: Retrospective analysis of phaco-DS data extracted from an ongoing glaucoma surgery database within Calderdale and Huddersfield NHS Trust. Two hundred and ninety-six eyes of 282 patients were included. Data included patient demographics, pre- and postoperative intraocular pressure (IOP), use of mitomycin C (MMC), spacer device implantation, and follow-up details including surgical success rates. IOP success criteria were: (A) IOP <19 mm Hg and/or 20% decrease from baseline and (B) IOP <16 mm Hg and/or 30% drop from baseline.
RESULTS: Mean follow-up was 63.5 ± 35.3 months. MMC was applied in 145 eyes (49%). Kaplan-Meier success rates in all eyes for criteria A were 89.1% and 80% with glaucoma medications (qualified success) and 81.2% and 68.3% without medications (unqualified success) at 2 and 5 years, respectively. Qualified success for criteria B was 72.4 and 61.4% and unqualified rates were 67.2 and 55.2% for the same time periods. Repeated-measures ANOVA showed significantly lower IOP in the phaco-DS with MMC group up to 3 years postoperatively (P = 0.002). Cox's proportional hazards for criteria B, however, showed no significant effect of MMC application in the long term (P = 0.2). Increasing age and laser goniopuncture were positively associated with success, whereas the absence of spacer devices was negatively associated. At last follow-up, 20% of eyes were on glaucoma medications. Complication rates were low with hypotony rates of 0.68%.
CONCLUSIONS: This study confirms the long-term safety and efficacy of phaco-DS as a primary glaucoma procedure.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app