BACKGROUND AND PURPOSE: To evaluate the variation in investigator-delineated volumes and assess plans from the radiotherapy trial quality assurance (RTTQA) program of SCALOP, a phase II trial in locally advanced pancreatic cancer.
MATERIALS AND METHODS: Participating investigators (n=25) outlined a pre-trial benchmark case as per RT protocol, and the accuracy of investigators' GTV (iGTV) and PTV (iPTV) was evaluated, against the trials team-defined gold standard GTV (gsGTV) and PTV (gsPTV), using both qualitative and geometric analyses. The median Jaccard Conformity Index (JCI) and Geographical Miss Index (GMI) were calculated. Participating RT centers also submitted a radiotherapy plan for this benchmark case, which was centrally reviewed against protocol-defined constraints.
RESULTS: Twenty-five investigator-defined contours were evaluated. The median JCI and GMI of iGTVs were 0.57 (IQR: 0.51-0.65) and 0.26 (IQR: 0.15-0.40). For iPTVs, these were 0.75 (IQR: 0.71-0.79) and 0.14 (IQR: 0.11-0.22) respectively. Qualitative analysis showed largest variation at the tumor edges and failure to recognize a peri-pancreatic lymph node. There were no major protocol deviations in RT planning, but three minor PTV coverage deviations were identified. .
CONCLUSIONS: SCALOP demonstrated considerable variation in iGTV delineation. RTTQA workshops and real-time central review of delineations are needed in future trials.
MATERIALS AND METHODS: Participating investigators (n=25) outlined a pre-trial benchmark case as per RT protocol, and the accuracy of investigators' GTV (iGTV) and PTV (iPTV) was evaluated, against the trials team-defined gold standard GTV (gsGTV) and PTV (gsPTV), using both qualitative and geometric analyses. The median Jaccard Conformity Index (JCI) and Geographical Miss Index (GMI) were calculated. Participating RT centers also submitted a radiotherapy plan for this benchmark case, which was centrally reviewed against protocol-defined constraints.
RESULTS: Twenty-five investigator-defined contours were evaluated. The median JCI and GMI of iGTVs were 0.57 (IQR: 0.51-0.65) and 0.26 (IQR: 0.15-0.40). For iPTVs, these were 0.75 (IQR: 0.71-0.79) and 0.14 (IQR: 0.11-0.22) respectively. Qualitative analysis showed largest variation at the tumor edges and failure to recognize a peri-pancreatic lymph node. There were no major protocol deviations in RT planning, but three minor PTV coverage deviations were identified. .
CONCLUSIONS: SCALOP demonstrated considerable variation in iGTV delineation. RTTQA workshops and real-time central review of delineations are needed in future trials.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app