Feasibility and safety of a fully covered self-expandable metal stent with antimigration properties for EUS-guided pancreatic duct drainage: early and midterm outcomes (with video).
Gastrointestinal Endoscopy 2016 Februrary
BACKGROUND AND AIMS: Recently, EUS-guided pancreatic duct drainage (EUS-PD) has been used for patients in whom endoscopic retrograde pancreatography (ERP) has failed. Stent-related adverse events such as stent migrations, failures in stent placement, or pancreatic fluid leakages have been of concern in transmural plastic stenting procedures. The aim of this study is to evaluate the feasibility and safety of EUS-PD with a fully covered self-expandable metal stent (FCSEMS) for patients with obstructive pancreatitis who failed ERP.
METHODS: Twenty-five consecutive patients with painful obstructive pancreatitis underwent EUS-PD with a FCSEMS after failed ERP. Technical and clinical success, adverse events, and stent patency were assessed.
RESULTS: EUS-PD was successful in all 25 patients (technical success rate, 100%), and symptoms improved in all patients (clinical success rate, 100%). EUS-guided pancreaticogastrostomy (n = 23), pancreaticoduodenostomy (n = 1), and pancreaticojejunostomy (n = 1) were performed. Pain scores improved significantly after FCSEMS placement (P = .001). Early mild grade adverse events occurred in 5 patients (20%), 4 with self-limited abdominal pain and 1 with minor bleeding. No other adverse events related to FCSEMS, including stent migration, stent clogging, pancreatic sepsis, and stent-induced ductal stricture, were observed during follow-up periods. Mean stent patency duration was 126.9 days during mean follow-up periods (221.1 days).
CONCLUSIONS: EUS-PD with an FCSEMS may be technically feasible and relatively safe for patients who fail conventional ERP. Further randomized trials comparing EUS-PD with long-term FCSEMS and plastic stents for patients with painful obstructive pancreatitis after failed ERCP should be encouraged.
METHODS: Twenty-five consecutive patients with painful obstructive pancreatitis underwent EUS-PD with a FCSEMS after failed ERP. Technical and clinical success, adverse events, and stent patency were assessed.
RESULTS: EUS-PD was successful in all 25 patients (technical success rate, 100%), and symptoms improved in all patients (clinical success rate, 100%). EUS-guided pancreaticogastrostomy (n = 23), pancreaticoduodenostomy (n = 1), and pancreaticojejunostomy (n = 1) were performed. Pain scores improved significantly after FCSEMS placement (P = .001). Early mild grade adverse events occurred in 5 patients (20%), 4 with self-limited abdominal pain and 1 with minor bleeding. No other adverse events related to FCSEMS, including stent migration, stent clogging, pancreatic sepsis, and stent-induced ductal stricture, were observed during follow-up periods. Mean stent patency duration was 126.9 days during mean follow-up periods (221.1 days).
CONCLUSIONS: EUS-PD with an FCSEMS may be technically feasible and relatively safe for patients who fail conventional ERP. Further randomized trials comparing EUS-PD with long-term FCSEMS and plastic stents for patients with painful obstructive pancreatitis after failed ERCP should be encouraged.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app