[Use of the anatomical cemented femoral stem SAS I: mid-term results].

PURPOSE OF THE STUDY In view of increasing interest in a relationship between the surface of an implant and its behaviour and longevity in total hip arthroplasty (THA), the aim of this study is to present the clinical and radiographic results, as well as complications, of hip replacement surgery using the cemented femoral stem SAS I. MATERIAL AND METHODS A total of 298 cemented femoral stems SAS I were implanted in 275 patients at our department between 1996 and 2005. The patient average age was 72.1 years, with the range from 64 to 92 years. The pre-operative diagnoses were as follows: primary osteoarthritis in 179 (30.1%); post-dysplastic osteoarthritis in 41 (13.7%); femoral neck fracture in 44 (14.8%); avascular necrosis of the femoral head in 23 (7.7%); rheumatoid arthritis in nine (3%) and other causes in two (0.7%) patients. Of the 275 patients who had the surgery, 186 (204 THAs) underwent clinical and X-ray examination at an average follow-up of 11.5 years (range, 8 to 17 years). The clinical results were used to calculate the Harris hip score and radiographic evaluation was based on antero-posterior views. RESULTS The group of 186 assessed patients (204 THAs) comprised 106 women and 80 men, who were on average 85.4 years old on evaluation (range, 72 to 92 years). Of the remaining patients, 62 patients (64 THAs) died from causes unrelated to the surgery and 27 patients (30 THAs) were lost to follow-up. The functional outcome of surgery assessed by the Harris hip score was excellent in 61 (32.8%), good in 94 (50.5%), satisfactory in 26 (14%) and poor in five (2.7%) patients. The 93.1% SAS I stem longevity was recorded in relation to aseptic loosening; reimplantation for this indication was performed in 14 THAs. No revision surgery for failure due to valgus/varus deviations of the stem was carried out. Of the 204 hips, 188 had femoral stems aligned in neutral, 12 (5.9%) in valgus and four (2%) in varus positions. DISCUSSION The anatomical femoral stem SAS I is an implant made to fit the proximal femur anatomy. Its highly polished surface allows for optimal fitting with the supporting bone and for even distribution of weight bearing. This results in a low rate of THA failure. In accordance with the relevant literature, the acetabular components is considered to be the weakest element in total hip replacement in terms of aseptic loosening and implant failure. At present, the SAS I stem has no Morse Eurocone taper and this is the chief obstacle hindering its more frequent use in endoprosthetics. CONCLUSIONS The results of our study are in agreement with those of other successfully implanted polished cemented femoral components. Key words: anatomical cemented femoral component, surface adjustment of the femoral stem, complications.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app