Inverse Relationship Between Membranous Septal Length and the Risk of Atrioventricular Block in Patients Undergoing Transcatheter Aortic Valve Implantation.

OBJECTIVES: This study sought to examine whether imaging of the atrioventricular (AV) membranous septum (MS) by computed tomography (CT) can be used to identify patient-specific anatomic risk of high-degree AV block and permanent pacemaker (PPM) implantation before transcatheter aortic valve implantation (TAVI) with self-expandable valves.

BACKGROUND: MS length represents an anatomic surrogate of the distance between the aortic annulus and the bundle of His and may therefore be inversely related to the risk of conduction system abnormalities after TAVI.

METHODS: Seventy-three consecutive patients with severe aortic stenosis underwent contrast-enhanced CT before TAVI. The aortic annulus, aortic valve, and AV junction were assessed, and MS length was measured in the coronal view.

RESULTS: In 13 patients (18%), high-degree AV block developed, and 21 patients (29%) received a PPM. Multivariable logistic regression analysis revealed MS length as the most powerful pre-procedural independent predictor of high-degree AV block (odds ratio [OR]: 1.35, 95% confidence interval [CI]: 1.1 to 1.7, p = 0.01) and PPM implantation (OR: 1.43, 95% CI: 1.1 to 1.8, p = 0.002). When taking into account pre- and post-procedural parameters, the difference between MS length and implantation depth emerged as the most powerful independent predictor of high-degree AV block (OR: 1.4, 95% CI: 1.2 to 1.7, p < 0.001), whereas the difference between MS length and implantation depth and calcification in the basal septum were the most powerful independent predictors of PPM implantation (OR: 1.39, 95% CI: 1.2 to 1.7, p < 0.001 and OR: 4.9, 95% CI: 1.2 to 20.5, p = 0.03; respectively).

CONCLUSIONS: Short MS, insufficient difference between MS length and implantation depth, and the presence of calcification in the basal septum, factors that may all facilitate mechanical compression of the conduction tissue by the implanted valve, predict conduction abnormalities after TAVI with self-expandable valves. CT assessment of membranous septal anatomy provides unique pre-procedural information about the patient-specific propensity for the risk of AV block.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app