Development and validation of an ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for the quantitative determination of rhamnolipid congeners.

Rhamnolipids (RLs) are synthesised as a complex mixture of congeners comprising either one or two molecules of rhamnose glycosidically linked to a dimer of 3-hydroxy fatty acids varying in chain length and degree of saturation. Currently, HPLC-MS/MS is the most precise and accurate method for RL determination, while accurate quantification is limited. In this study, a rapid ultra pressure liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the rapid and quantification of individual RL congeners. Increased RLs specificity was achieved using tandem mass spectrometry in multiple reaction monitoring (MRM) mode which was used to quantify RL isomer pairs such as Rha-Rha-C8-C10/Rha-Rha-C10-C8 which are difficult to resolve chromatographically. UPLC showed an 18-fold reduction in retention time for Rha-Rha-C10-C10 (1.07 min) and a 17-fold reduction for Rha-C10-C10 (1.36), the major rhamnolipids present, compared to HPLC, with a total run time less than 2.2 min. The results show that the linear range for the main RL congeners (Rha-C10-C10 and Rha-Rha-C10-C10) is 0.1 to 100 μg/mL. The LOD and LOQ for Rha-C10-C10 is 0.05 and 0.1 μg/mL and for Rha-Rha-C10-C10 is 0.1 and 0.5 μg/mL, respectively. The method was validated for linearity, intra- and inter-day precision and accuracy in accordance with FDA guidelines. The method was applied for the quantification of 14 individual RL congeners produced by Pseudomonas aeruginosa ST5 and comparison of RLs composition on four different carbon sources. Quantification of the individual congeners showed a conserved congener distribution irrespective of carbon source with a preferential selection for C10 β-hydroxyacids as the lipid component of RLs. The only statistically significant differences detected were between actual RL yields on the various carbon sources.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app