We have located links that may give you full text access.
Flow Diverter Stents for the Treatment of Anterior Cerebral Artery Aneurysms: Safety and Effectiveness.
Clinical Neuroradiology 2017 March
BACKGROUND AND PURPOSE: Flow diverter stents (FDSs) are increasingly used for the treatment of intracranial aneurysms. Initially developed for the management of giant and large aneurysms, their indications have progressively expanded. The purpose of our study was to evaluate the safety and effectiveness of FDSs for the treatment of anterior cerebral artery (ACA) aneurysms.
MATERIALS AND METHODS: Among the 94 consecutive patients treated for 100 intracranial aneurysms by means of FDSs in our institution from October 2010 to January 2015, eight aneurysms (8 %) in seven patients were located on the ACA. Three aneurysms were located on the A1 segment, three aneurysms on the anterior communicating artery (ACom) and two on the A2-A3 junction. In three cases, FDS was used for angiographic recurrence after coiling. Five patients were treated with a Pipeline embolization device, one with a NeuroEndograft and the last one with a Silk FDS.
RESULTS: Treatment was feasible in all cases. No technical difficulty was reported. No acute or delayed clinical complication was recorded. Modified Rankin Scale was 0 for six patients and one for one patient. Mean angiographic follow-up was 9.7 ± 3.9 months (range 6-15). Total exclusion was observed in five aneurysms (71.4 %) and neck remnant in two (28.6 %) cases. One patient refused the control DSA.
CONCLUSION: Our series shows the safety and effectiveness of FDSs for the treatment of ACA aneurysms.
MATERIALS AND METHODS: Among the 94 consecutive patients treated for 100 intracranial aneurysms by means of FDSs in our institution from October 2010 to January 2015, eight aneurysms (8 %) in seven patients were located on the ACA. Three aneurysms were located on the A1 segment, three aneurysms on the anterior communicating artery (ACom) and two on the A2-A3 junction. In three cases, FDS was used for angiographic recurrence after coiling. Five patients were treated with a Pipeline embolization device, one with a NeuroEndograft and the last one with a Silk FDS.
RESULTS: Treatment was feasible in all cases. No technical difficulty was reported. No acute or delayed clinical complication was recorded. Modified Rankin Scale was 0 for six patients and one for one patient. Mean angiographic follow-up was 9.7 ± 3.9 months (range 6-15). Total exclusion was observed in five aneurysms (71.4 %) and neck remnant in two (28.6 %) cases. One patient refused the control DSA.
CONCLUSION: Our series shows the safety and effectiveness of FDSs for the treatment of ACA aneurysms.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app