JOURNAL ARTICLE
OBSERVATIONAL STUDY
Add like
Add dislike
Add to saved papers

Donor Death After Selective Fetoscopic Laser Surgery for Twin-Twin Transfusion Syndrome.

OBJECTIVE: To assess the incidence, timing, and risk factors for death of the donor fetus after fetoscopic laser surgery, we evaluated our cohort of patients who underwent the procedure for twin-twin transfusion syndrome.

METHODS: This was a prospective cohort study of 166 consecutive patients with twin-twin transfusion syndrome at a single center. Fetal death was diagnosed by ultrasonography after surgery and before onset of labor. Risk factors for death of the donor twin were identified on univariate analysis and then subjected to multivariate, stepwise, logistic regression analysis.

RESULTS: Donor demise occurred in 20 (13%) cases and recipient twin death occurred in four (2.6%). The median procedure to death interval was 4 days (range 1-89 days). Risk factors for donor death were fetal growth discordance greater than 30% (odds ratio [OR] 6.7, 95% confidence interval [CI] 2-23), reverse end-diastolic velocity in the donor umbilical artery (OR 25.0, 95% CI 2-290), a marginal and velamentous cord insertion (OR 4.4, 95% CI 1-19), and an increased number of anastomoses (OR 1.2, 95% CI 1.1-1.5). All four donors with both fetal growth discordance greater than 30% and reverse end-diastolic velocity in the donor umbilical artery resulted in a demise.

CONCLUSION: Four risk factors significantly affecting acute and delayed donor demise after fetoscopic laser surgery were identified. The presence of both fetal growth discordance greater than 30% and reverse end-diastolic velocity in the donor umbilical artery was highly predictive of donor demise in our cohort. Knowledge of these risk factors can aid in counseling and assist patients in choosing the most appropriate intervention in the management of twin-twin transfusion syndrome.

LEVEL OF EVIDENCE: III.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app