Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Transepithelial Riboflavin Absorption in an Ex Vivo Rabbit Corneal Model.

PURPOSE: To measure depth-specific riboflavin concentrations in corneal stroma using two-photon fluorescence microscopy and compare commercially available transepithelial corneal collagen cross-linking (CXL) protocols.

METHODS: Transepithelial CXL riboflavin preparations--MedioCross TE, Ribocross TE, Paracel plus VibeX Xtra, and iontophoresis with Ricrolin+--were applied to the corneal surface of fresh postmortem rabbit eyes in accordance with manufacturers' recommendations for clinical use. Riboflavin 0.1% (VibeX Rapid) was applied after corneal epithelial debridement as a positive control. After riboflavin application, eyes were snap frozen in liquid nitrogen. Corneal cross sections 35-μm thick were cut on a cryostat, mounted on a slide, and imaged by two-photon fluorescence microscopy. Mean (SD) concentrations were calculated from five globes tested for each protocol.

RESULTS: Peak riboflavin concentration of 0.09% (± 0.01) was observed within the most superficial stroma (stromal depth 0-10 μm) in positive controls (epithelium-off). At the same depth, peak stromal riboflavin concentrations for MedioCross TE, Ricrolin+, Paracel/Xtra, and Ribocross TE were 0.054% (± 0.01), 0.031% (0.003), 0.021% (± 0.001), and 0.015% (± 0.004), respectively. At a depth of 300 μm (within the demarcation zone commonly seen after corneal cross-linking), the stromal concentration in epithelium-off positive controls was 0.075% (± 0.006), while at the same depth MedioCross TE and Ricrolin+ achieved 0.018% (± 0.006) and 0.016% (0.002), respectively. None of the remaining transepithelial protocols achieved concentrations above 0.005% at this same 300-μm depth. Overall, MedioCross TE was the best-performing transepithelial formulation.

CONCLUSIONS: Corneal epithelium is a significant barrier to riboflavin absorption into the stroma. Existing commercial transepithelial CXL protocols achieve relatively low riboflavin concentrations in the anterior corneal stroma when compared to gold standard epithelium-off absorption. Reduced stromal riboflavin concentration may compromise the efficacy of riboflavin/ultraviolet corneal CXL.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app