Point-of-care testing and INR within-subject variation in patients receiving a constant dose of vitamin K antagonist.

Many patients treated with vitamin K antagonists (VKA) determine their INR using point-of-care (POC) whole blood coagulation monitors. The primary aim of the present study was to assess the INR within-subject variation in self-testing patients receiving a constant dose of VKA. The second aim of the study was to derive INR imprecision goals for whole blood coagulation monitors. Analytical performance goals for INR measurement can be derived from the average biological within-subject variation. Fifty-six Thrombosis Centres in the Netherlands were invited to select self-testing patients who were receiving a constant dose of either acenocoumarol or phenprocoumon for at least six consecutive INR measurements. In each patient, the coefficient of variation (CV) of INRs was calculated. One Thrombosis Centre selected regular patients being monitored with a POC device by professional staff. Sixteen Dutch Thrombosis Centres provided results for 322 selected patients, all using the CoaguChek XS. The median within-subject CV in patients receiving acenocoumarol (10.2 %) was significantly higher than the median CV in patients receiving phenprocoumon (8.6 %) (p = 0.001). The median CV in low-target intensity acenocoumarol self-testing patients (10.4 %) was similar to the median CV in regular patients monitored by professional staff (10.2 %). Desirable INR analytical imprecision goals for POC monitoring with CoaguChek XS in patients receiving either low-target intensity acenocoumarol or phenprocoumon were 5.1 % and 4.3 %, respectively. The approximate average value for the imprecision of the CoaguChek XS, i. e. 4 %, is in agreement with these goals.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app