The Effect of Knee Flexion Angle on the Neurovascular Safety of All-Inside Lateral Meniscus Repair: A Cadaveric Study.

Arthroscopy 2015 November
PURPOSE: To evaluate if different knee flexion angles can modify the neurovascular injury risk during lateral meniscus repair.

METHODS: Twenty cadaveric knees were studied. An all-inside suture device (FasT-Fix; Smith & Nephew, Andover, MA) was placed at the posterior horn and at the medial and lateral limits of the popliteal hiatus. The minimal distances between the device and the popliteal artery and peroneal nerve were measured with the knee at 90°, 45°, and 0° of flexion through a limited posterolateral arthrotomy.

RESULTS: The distance between the device when inserted at the lateral edge of the popliteal hiatus and the peroneal nerve decreased from a median of 26 mm (interquartile range [IQR], 3.5 mm; range, 19 to 29 mm) at 90° to 21.5 mm (IQR, 4.5 mm; range, 14 to 25 mm) at 45° and 15.5 mm (IQR, 6.5 mm; range, 4 to 20 mm) at 0° (significant differences, P < .001). The distance between the device when inserted at the medial edge of the popliteal hiatus and the peroneal nerve decreased from 16 mm (IQR, 3.3 mm; range, 9 to 21 mm) at 90° to 12 mm (IQR, 4.3 mm; range, 9 to 16 mm) at 45° and 7 mm (IQR, 4.0; range, 4 to 15 mm) at 0° (significant differences, P < .001). The distance between the device when inserted at the medial edge of the popliteal hiatus and the popliteal artery decreased from 21 mm (IQR, 5.0 mm; range, 11 to 27 mm) at 90° to 19 mm (IQR, 5.0 mm; range, 10 to 23 mm) at 45° and 16 mm (IQR, 7.5 mm; range, 10 to 23 mm) at 0° (significant differences, P < .001). The distance between the device when inserted 5 mm lateral to the posterior root of the lateral meniscus and the popliteal artery decreased from 13 mm (IQR, 4.3 mm; range, 7 to 27 mm) at 90° to 10.5 mm (IQR, 4.3 mm; range, 4 to 19 mm) at 45° and 5.5 mm (IQR, 4.0 mm; range, 0 to 14 mm) at 0° (significant differences, P < .001).

CONCLUSIONS: The risk of injury to the popliteal artery or to the peroneal nerve during all-inside repair of the posterior half of the lateral meniscus is lower at 90° of flexion and increases with knee extension to 45° and 0°.

CLINICAL RELEVANCE: All-inside meniscal repair of the lateral meniscus is safer with the knee at 90° of flexion.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app