We have located links that may give you full text access.
Comparing effects of low and high-flow anesthesia on hemorheology and coagulation factors.
OBJECTIVES: In the current study, we compared the effects of low- and high-flow anesthesia techniques on hemorheology and coagulation parameters in patients who received sevofluran.
METHODS: Forty patients classified as Risk Group I-II according to American Society of Anesthesiologists' (ASA) guidelines who were scheduled to undergo general anesthesia were randomly assigned to one of two groups. Low-flow anesthesia was administered to the first group, and high-flow anesthesia was used in the second group. Blood samples were obtained in the preoperative and peroperative periods (at 60 and 120 min) for determination of blood and plasma viscosity, plasma oncotic pressure, international normalized ratio (INR), phorotrombin time (PT), activated partial phorotrombin time (aPTT) and fibrinogen. Blood was also drawn for analysis of factor VIII (FVIII) activity, which was measured in the preoperative period and at postoperative six hour.
RESULTS: The peroperative plasma viscosity was significantly low in Group 1 relative to Group 2. aPTT was significantly elevated at 60 minutes in Group 1 relative to Group 2, but the increase at 120 minutes was not significant.
CONCLUSION: The effects of low-flow anesthesia on hemorheology were greater than those of high-flow anesthesia.
METHODS: Forty patients classified as Risk Group I-II according to American Society of Anesthesiologists' (ASA) guidelines who were scheduled to undergo general anesthesia were randomly assigned to one of two groups. Low-flow anesthesia was administered to the first group, and high-flow anesthesia was used in the second group. Blood samples were obtained in the preoperative and peroperative periods (at 60 and 120 min) for determination of blood and plasma viscosity, plasma oncotic pressure, international normalized ratio (INR), phorotrombin time (PT), activated partial phorotrombin time (aPTT) and fibrinogen. Blood was also drawn for analysis of factor VIII (FVIII) activity, which was measured in the preoperative period and at postoperative six hour.
RESULTS: The peroperative plasma viscosity was significantly low in Group 1 relative to Group 2. aPTT was significantly elevated at 60 minutes in Group 1 relative to Group 2, but the increase at 120 minutes was not significant.
CONCLUSION: The effects of low-flow anesthesia on hemorheology were greater than those of high-flow anesthesia.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app