COMPARATIVE STUDY
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Impella 5.0 Support in INTERMACS II Cardiogenic Shock Patients Using Right and Left Axillary Artery Access.

Artificial Organs 2015 August
The catheter-based Impella 5.0 left ventricular assist device (LVAD) is a powerful and less invasive alternative for patients in cardiogenic shock. The use of this device as a primary mechanical circulatory support strategy in INTERMACS II patients should be evaluated. From April 2014 to August 2014, eight Impella 5.0 devices were implanted in seven patients via the axillary artery access (six right and two left). We analyzed the outcome of the four patients in whom the Impella 5.0 device was implanted for the purpose of primary stabilization of cardiogenic shock (INTERMACS II). The remaining three patients had a contraindication for a permanent LVAD and received the device for prolonged weaning from extracorporeal life support (ECLS) system. The implantation of the Impella 5.0 was technically successful in all patients and resulted in the stabilization of the clinical situation. All four patients could be bridged to a long-term device (n = 3) or to cardiac recovery (n = 1). In one patient, 2 days of ECLS support was necessary because of pump thrombosis after 31 days of Impella 5.0 support. One patient with bronchopneumonia had the Impella 5.0 exchanged from the right to the left axillary artery after 22 days of support because of the progressive loss of purge flow and the need for longer bridging to a permanent LVAD. The last patient was supported for giant-cell myocarditis for 22 days and bridged to cardiac recovery. All patients were transferred to the intensive care unit with the Impella device in place. In INTERMACS II situations, the implantation of the Impella 5.0 via the right or left axillary access allowed additional time for decision making. Early patient mobilization, including walking with the Impella device in place, optimized the conditions for either weaning or the implantation of a permanent LVAD. This novel technique of left axillary approach leads to more flexibility in the case of anatomical- or device-related contraindications to right-side access, or when the device needs to be exchanged while continuous support is necessary.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

Managing Alcohol Withdrawal Syndrome.Annals of Emergency Medicine 2024 March 26

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app