Ultrasound imaging of the diagonal dimension of the deep cervical flexor muscles: A reliability study on healthy subjects.

The purpose of this study is to assess the reliability of a new ultrasound imaging (USI) parameter and procedure for the evaluation of the size of the deep cervical flexor (DCF) muscles. Thirty-one healthy male subjects (21.6 ± 2.5 years old) participated in this study. Two images of the diagonal dimension (DD) of the DCF of the subjects, at 1.5 fingerbreadths below the laryngeal prominence of the thyroid cartilage in a relaxed state, were taken on separate days with a 1-week interval. The intraclass correlation coefficient between the days was 0.82 (95% confidence interval, 0.65-0.91). The standard error of measurement and minimal detectable change were 0.8 mm and 2.1 mm, respectively. The results indicated that the DD may be used as a reliable USI parameter to measure the DCF thickness in healthy subjects.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app